power transformer
"
750kVA Core Type 3 Phase Transformer , Oil Type Pad Mounted Transformer IP55 Rating
750kVA Core Type 3 Phase Transformer, Oil Type Pad Mounted Transformer IP55 Rating Product Overview 750kVA 3 Phase Core Transformer Oil Type Voltage Electric Transformer designed for reliable power distribution with robust construction and high efficiency. Technical Specifications Attribute Value Frequency 50Hz, 60Hz, Coil Number Two Windings Application Distribution System Output Voltage 415V, 110V, 220V, 380V, 400V, 440V Input Voltage 10.5kV, 3kV, 12.47kV, 6.6kV, 6kV, 6.3kV
750KVA-1000KVA Three Phase Pad Mounted Transformer Oil Cooling Step Up Operation
750KVA-1000KVA Three Phase Pad Mounted Transformer Oil Cooling Step Up Operation Product Specifications Attribute Value Frequency 50Hz, 60Hz, 50/60 Hz Application Distribution System Output Voltage 380V, 400V, 440V, 480V Input Voltage 10kV Product Name Three Phase Oil Immersed Transformer Rated Capacity 750KVA-1000KVA Cooling Method Oil Cooling Impedance 5.8% Standard ANSI / IEEE / DOE 2016 Enclosure Rating NEMA 3R or NEMA 4X UL Certificate Numbers UL-US-2431836-0, UL-CA
Electric Step Up Transformer Medium Voltage Instrument Transformers 2500 Kva Oil Immersed
Electric Step Up Transformer Medium Voltage Instrument Transformers 3750 KVA Oil Immersed Product Specifications Type Distribution transformer Material Copper, 100% Copper Wire Frequency 50Hz, 60Hz Shape Rectangle Winding Material Copper Application Power Phase Three Coil Structure Wound Coil Coil Number Multi-winding coil Input Voltage 3kV, 6kV, 10kV, 15kV, Output Voltage 11kV, 110V, 220V, 380V, 440V, 480V, 415V, 400V Standard IEC ANSI IEEE Rated capacity 75KVA-2500KVA
75kVA Three Phase Pad Mounted Distribution Transformers For Outdoor Applications
75kVA Three Phase Pad Mounted Distribution Transformers Efficient, Reliable, and Safe Power Distribution for Outdoor Applications Product Specifications Capacity (KVA) HV Tapping range LV No-load loss Load loss Impedance Efficiency 75 2400 4160 7200 7620 12000 12470 13200 13800 14400 19920 24940 34500 2X2.5% 110 120 208 240 277 347 415 416 480 600 690 130 100 4.0-6.3 99.03 Technical Attributes Type distribution transformer, ZGS Material Copper, 100% Copper Wire Frequency
Single Phase Pole Mounted Distribution Transformer Oil Cooling 15kVA 37.5kVA 100kVA 75kVA
Single Phase Pole Mounted Distribution Transformer Oil Cooling 15kVA 37.5kVA 100kVA 75kVA Product Specifications Attribute Value Frequency 50Hz, 60Hz Phase Single Phase Coil Structure Shell-Type Coil, layer coil, fully sealed construction, round coil, Disc Coil Output Voltage 10kV, 415V, 110V, 220V, 380V, 400V, 440V, 480V, 11kV Input Voltage 11kV, 10.5kV, 3kV, 12.47kV, 6.6kV, 6.3kV, 6kV, 10kV Type Isolation Transformer, Voltage Regulator Transformer, AUTOTRANSFORMER, Oil
1600kVA 10kV to 0.4kV Oil-Immersed Distribution Transformer
10kV Voltage Transformer - 1600kVA 0.4kV Distribution Transformer (3 Phase Oil-Immersed) High quality electrical transformers designed for reliable power distribution with competitive pricing. S11 Type Energy-Efficient Secondary Oil-Immersed Transformer Specifications Rated Capacity (KVA) Vector Group Voltage Combination No-load Loss Load Loss Impedance 1600 Dyn11 10 6.3 6 1640 14500 4.5 Installation Resources Process Documentation About HENTG POWER HENTG POWER is a
35kV Class 2500kVA Capacity Oil Immersed Power Distribution Transformer with 6.3-11kV Rated LV for Industrial Grids
35kV Class Power Distribution Transformer 2500kVA Capacity Oil Filled 3 Phase Electronic Transformer 2500KVA Product Overview 35kV oil filled distribution transformer designed for step-up applications in power distribution systems, with capacity range from 1500KVA to 2500KVA. Key Specifications Frequency: 50Hz, 60Hz, 50/60Hz Phase: Three Application: Distribution system Output Voltage: 10kV, 415V, 110V, 220V, 380V, 400V, 440V Input Voltage: 11kV, 10.5kV, 3kV, 6.6kV, 12.47kV,
Oil-Immersed 630KVA 1000KVA Pre-Installed Box-type Substation 6KV 10KV YB Compact Transformer Distribution
Oil-Immersed 630KVA 1000KVA Pre-Installed Box-type Substation HENTG POWER Oil-Immersed 630KVA 1000KVA Pre-Installed Box-type Substation 6KV 10KV YB Compact Transformer Distribution Typical Application Scenario The HENTG POWER Oil-Immersed Pre-Installed Box-Type Substation is widely applied in industrial parks, urban infrastructure projects, renewable energy sites, and commercial developments where fast installation, limited space, and reliable medium-voltage power distributio
Three Phase Box Type Substation with 400V-690V Output Voltage and 20kV Rated Voltage for Power Distribution
Three Phase Box Type Substation with 400V-690V Output Voltage and 20kV Rated Voltage for Power Distribution Consulting Process Step 1: We respond to inquiries within 1 hour, recommending suitable transformers based on your requirements. We provide competitive quotations and flexible payment terms. Our professional drawing and technical teams will confirm all drawing details with you within 7 days after payment, including technical specifications, weight, and parts list. Step