Three Phase Pad Mounted Transformer with 500KVA to 1000KVA Capacity for 15KV Class Medium Voltage and 480Y277V Low Voltage Output

Product Summary

Three Phase Pad Mounted Transformer 500KVA 750KVA 1000KVA 15KV 480Y277V Oil Filled for Commercial Distribution Product Overview The Three Phase Pad Mounted Transformer is an outdoor oil filled distribution transformer designed for medium voltage power distribution in commercial, industrial, utility, ...

Key Attributes
Brand Name: HENTG POWER
Place of Origin: CHINA
Certification: IEC60076
MOQ: 1
Payment Terms: L/C,D/A,D/P,T/T
Standard Packaging: Wooden case
Product Custom Attributes
Highlight

500KVA to 1000KVA Capacity Pad Mounted Transformer

,

15KV Class Medium Voltage Distribution Transformer

,

480Y277V Low Voltage Output Three Phase Pad Mounted Transformer

Usage:
Power,Instrument,power Grid System,High Frequency,Distribution Transformer
Coil Structure:
TOROIDAL
Lv Voltage:
480Y/277 V/others
Protectionfeatures:
Pressure Relief Device, Surge Arresters
Material:
Alumnium/copper
Installation:
Indoor/Outdoor
Transformer Type:
Pad Mounted Transformer
Coil Number:
Customized
Capacity:
2MVA (2000KVA)/costomize
Productname:
Three Phase Pad Mounted Transformer
Shape:
Rectangle
Product Description
Three Phase Pad Mounted Transformer 500KVA 750KVA 1000KVA 15KV 480Y277V Oil Filled for Commercial Distribution
Product Overview
Three Phase Pad Mounted Transformer installation

The Three Phase Pad Mounted Transformer is an outdoor oil filled distribution transformer designed for medium voltage power distribution in commercial, industrial, utility, renewable energy and infrastructure projects.

Available in 500KVA, 750KVA and 1000KVA ratings, this pad mounted transformer is designed for 15KV class primary distribution systems with 480Y277V low voltage output, with project specific voltage, connection and protection configurations available according to local grid requirements.

The compact ground mounted construction provides a practical solution where underground medium voltage cables are used and where a transformer needs to be installed directly on a concrete pad without a conventional transformer room.

Typical Applications
  • Commercial buildings and shopping centers
  • Industrial plants and manufacturing facilities
  • Urban and rural distribution networks
  • Solar PV and renewable energy projects
  • Battery energy storage projects
  • Mining and mineral processing facilities
  • Agricultural and irrigation systems
  • Hotels, hospitals and large infrastructure
  • Utility distribution projects
  • EPC electrical distribution projects
Key Features
Flexible 500KVA to 1000KVA Capacity

Available in 500KVA, 750KVA and 1000KVA, covering different power distribution requirements for commercial buildings, industrial facilities, renewable energy projects and utility applications.

15KV Class Medium Voltage Design

Designed for 15KV class distribution systems, with primary voltage options configurable according to the customer's local grid, project drawings and utility requirements.

480Y277V Low Voltage Output

The 480Y277V secondary system is suitable for three-phase commercial and industrial power distribution, supporting motors, HVAC systems, pumps, lighting systems and other electrical loads.

Outdoor Pad Mounted Construction

The transformer is installed directly on a concrete foundation, reducing the need for a dedicated indoor transformer room and providing a compact solution for outdoor electrical distribution.

Flexible Protection and Connection Configuration

Depending on project requirements, the transformer can be configured with radial feed or loop feed, high voltage fuses, load break switch, bushings, grounding terminals, tap changer and other accessories.

Technical Specifications
Three Phase Pad Mounted Transformer technical diagram
Parameter Typical Specification
Product Type Three Phase Pad Mounted Transformer
Transformer Type Oil Filled Distribution Transformer
Rated Capacity 500KVA 750KVA 1000KVA
Phase Three Phase
Frequency 60Hz or project specified
HV Class 15KV Class
Typical HV Voltage 12.47KV 13.2KV 13.8KV or project specified
LV Voltage 480Y277V
Cooling ONAN
Installation Outdoor Pad Mounted
Insulating Medium Mineral Oil or optional alternative
Winding Material Copper or Aluminum according to design
Tap Changer De Energized Tap Changer
Typical Tap Range ±2 × 2.5% or project specified
Core and Winding

The transformer uses a high-efficiency magnetic core and carefully designed high and low voltage windings to control no-load losses, load losses, temperature rise and voltage regulation.

Oil Insulation System

The active part is immersed in insulating oil for electrical insulation and heat transfer. The oil circulation and external cooling system help transfer heat from the winding and core to the surrounding environment during continuous operation.

Pad Mounted Enclosure Features
  • Lockable cabinet doors
  • High voltage compartment
  • Low voltage compartment
  • Grounding terminals
  • Lifting lugs
  • Pressure relief device
  • Oil level indicator
  • Drain and sampling valve
  • Nameplate
  • Cable termination compartment
  • Fuse protection
  • Load break switching equipment when required
Application Solutions
Different Grid Voltages

The transformer can be configured according to the actual project voltage and single line diagram rather than using one fixed configuration. Our engineering team can prepare corresponding technical proposals based on your specific requirements.

Outdoor Installation and Harsh Climate

The transformer can be configured with an outdoor-rated cabinet, suitable surface treatment, appropriate cooling design and project-specific environmental requirements for challenging conditions including high temperatures, humidity, coastal salt exposure, and dust.

Limited Installation Space

The pad mounted design provides a compact ground-level installation method, reducing the requirement for a conventional indoor transformer room.

Long Distance Between Transformer and Load

The 500KVA, 750KVA and 1000KVA capacity range allows selection of appropriate transformer rating according to calculated load demand, considering connected load, demand factor, motor starting requirements and future expansion.

Frequently Asked Questions
What capacity options are available for this three phase pad mounted transformer?

The listed configuration covers 500KVA, 750KVA and 1000KVA. Other ratings can also be evaluated according to the project load and distribution requirements.

Can the transformer be customized for different Latin American countries?

Yes. Primary voltage, secondary voltage, frequency, connection type, BIL, impedance, tap range, protection configuration and enclosure requirements can be specified according to the project.

Can you provide 480Y277V secondary voltage?

Yes. 480Y277V is a standard configuration for this type of three-phase pad-mounted distribution transformer. Other secondary voltage options can be evaluated according to the project requirement.

Can you provide radial feed and loop feed configurations?

Yes. Both configurations can be considered. Radial feed is suitable for simpler distribution systems, while loop feed can provide greater flexibility for medium voltage distribution networks.

What information should an EPC contractor provide for quotation?

For an accurate quotation, please provide: KVA rating + HV voltage + LV voltage + frequency + connection group + BIL + impedance + tap range + radial or loop feed + protection requirements + installation environment. If available, please also send the single line diagram and technical specification.

Send us your transformer specifications or SLD today and get a project matched Three Phase Pad Mounted Transformer solution.
Contact Us
You Can Contact Us At Anytime!