HENTG POWER 3000kVA 34.5kV to 480V Liquid-Filled Pad Mounted Transformer for Industrial Power Distribution
HENTG POWER 3000kVA pad-mounted transformer: 34.5kV to 480V step-down, 3-phase liquid-filled design. ANSI/IEEE compliant with loop feed for redundancy, dead-front safety, and copper windings. Ideal for North American utility & industrial applications.
3000kVA Pad Mounted Transformer
,34.5kV to 480V Power Transformer
,Liquid-Filled Distribution Transformer

- Loop feed design for network redundancy
- Dead-front primary bushings for operator safety
- Self-cooled KNAN system with optional fans for higher overload capacity
- ANSI/IEEE compliance for easy utility approval
| Type | Pad-Mounted, Compartmental |
|---|---|
| Cooling | KNAN, Self-Cooled |
| Operation | Step-Down (Not approved for Step-Up) |
| Phase | Three-Phase |
| Frequency | 60 Hz |
| Impedance | 5.75% (Target) |
| Temperature Rise | 55/65°C |
| Insulation Class | Class E (120°C / 248°F) |
| Base Rating | 3.0 MVA (3000 kVA) |
|---|---|
| With Fans | 3.36 MVA (3360 kVA) |
| HV Voltage | 34,500 V |
| HV Class | 35 kV |
| HV BIL | 150 kV |
| LV Voltage | 480Y/277 V |
| LV Class | 1.2 kV |
| Vector Group | Dyn1 |
| Configuration | Delta |
|---|---|
| Bushing Type | 600A, 35 kV Class, Deadbreak (IEEE 386) |
| Front | Dead Front |
| Terminal Arrangement | V-Type |
| Connections | (6) Primary Bushings for Elbow Connectors |
| Surge Arresters | (3) 36 kV Class Elbow Arresters, 29 kVrms |
| Taps | 5-Position De-Energized Tap Changer (±2 × 2.5% / 2 FCAN / 2 FCBN) |
| Configuration | Wye-N |
|---|---|
| Front | Live Front |
| Terminal Arrangement | Staggered |
| Terminals | NEMA 12-Hole Spade |
| Bushings | Externally Clamped Epoxy Bushings with Copper Studs |
- ANSI/IEEE Compliance: Simplifies utility approvals and inspections
- Loop Feed Design: Ensures continuous power and network redundancy
- Dead-Front Safety: Reduces operator risk and improves maintenance safety
- Flexible Tap Changer: Accommodates voltage variations in distribution networks
- Self-Cooled with Optional Fans: Supports higher load conditions and extends service life
- Durable Construction: Compartmental design protects HV/LV sections and minimizes maintenance
- 3 phase pad mounted transformers
- Compartmental type loop feed transformers
- Utility distribution transformers
- Industrial and commercial power solutions
-
500kVA 3 Phase Pad Mounted Electrical Transformer Weatherproof Oil Immersed Cooling
500kVA 3 Phase Pad Mounted Electrical Transformer Weatherproof Oil Immersed Cooling Product Specifications Attribute Value Type Distribution transformer, power transformer, Oil-filled Transformer Frequency 50Hz, 60Hz Winding Material Aluminum Application Power Phase Three Coil Structure TOROIDAL Coil Number Multi-winding coil Input Voltage 10kV Output Voltage 400V, 440V, 480V Cooling Method ONAN ONAF OFAF Transformer type Toroidal Transformer Technical Specifications Capacity
-
Outdoor Rated Three Phase Pad Mounted Transformer 300kVA With Tamper Proof Cabinet
Outdoor Rated Three Phase Pad Mounted Transformer 300kVA With Tamper Proof Cabinet Product Specifications Type Distribution transformer, power transformer, Oil-filled Transformer Frequency 50Hz, 60Hz Winding Material Aluminum Application Power Distribution System Phase Three Coil Structure TOROIDAL Input Voltage 10kV Output Voltage 400V, 380V, 440V, 480V Cooling Method ONAN ONAF OFAF Capacity (KVA) HV Tapping range LV No-load loss Load loss Impedance Efficiency 75 2400 4160
-
Three Phase Pad Mounted Transformer Step Up Step Down 500KVA 750KVA 1000kVA 1500KVA
Three Phase Pad Mounted Transformer Step Up Step Down 500KVA 750KVA 1000kVA 1500KVA Product Specifications Attribute Value Frequency 60Hz Application Power Transformer Output Voltage 110V, 220V, 380V, 400V, 440V, 480V Input Voltage 11kV, 10.5kV, 3kV, 6.6kV, 6.3kV Type Pad Mounted Transformer Standard DOE/IEC60076/IEEE Warranty 2 Years Vector Group Dyn11/Yyn0/Yd11/YNd11 Usage Outdoor Power Line Operation High Voltage 11kv 10kv 6.3kv 6kv 14.4KV 25KV 34.5KV Low Voltage 120-240