Durable safe Reliable Aluminum & Cooper 100kVA Dry Type Distribution Transformer 0.4KV 11KV IEC60076 for Commercial Electrical Systems Manufacturer
100kVA dry-type transformer with IEC60076 compliance, fire-resistant epoxy resin design, and customizable copper/aluminum windings. Offers high efficiency, strong short-circuit resistance, and low maintenance for commercial electrical systems.

This series of dry type transformers is designed with advanced vacuum pressure impregnation (VPI) and epoxy resin encapsulation technology, offering high safety, low loss, and strong short-circuit resistance.
It is widely used in commercial buildings, industrial power distribution, data centers, and high-temperature regions.
Compliant with IEC60076 international standards, the transformer supports customized copper or aluminum winding options, making it suitable for various voltage levels and global electrical infrastructure projects.
- High safety epoxy resin encapsulation, oil-free and fire-resistant design
- Low loss silicon steel core for high efficiency operation
- Strong short-circuit withstand capability
- Optimized thermal design for high-temperature regions
- Low maintenance and long service life
- Customizable design for voltage, capacity, and materials
| Item | Specification |
|---|---|
| Rated Capacity | 50kVA – 2500kVA (customizable) |
| HV Voltage | 6kV / 10kV / 11kV / 13.8kV |
| LV Voltage | 400V / 415V / 690V |
| Frequency | 50Hz / 60Hz |
| Phase | Three Phase |
| Cooling Method | AN / AF |
| Insulation Class | F / H |
| Temperature Rise | ≤100K |
| Vector Group | Dyn11 / Yyn0 |
| Winding Material | Copper / Aluminum |
| Protection Class | IP20 / IP23 / IP54 |
| Standard | IEC60076 |
| Noise Level | ≤55–65dB |
| Ambient Temp | -25℃ ~ +50℃ (optional high-temp design) |






- Overheating in hot climate regions
- Fire risk in oil-filled transformers
- High maintenance cost
- Reduced lifespan under heavy load
- F/H class high-temperature insulation system
- Optimized cooling duct design for better heat dissipation
- Oil-free structure eliminates fire and leakage risks
- Optional forced air cooling system (AF)
- Reinforced winding structure for extreme conditions
-
Epoxy Resin Dry Type Distribution Transformer 80 Kva 3 Phase With Triple Winding Coil
Epoxy Resin Dry Type Distribution Transformer 80 Kva 3 Phase With Triple Winding Coil Product Specifications Attribute Value Type Power transformer, distribution transformer, Dry Type Transformer Frequency 50Hz, 60Hz Winding Material Copper Application Power Phase Three Coil Structure Layered Winding Coil Number Triple-winding coil Input Voltage 10kV Output Voltage 400V Cooling Method Fan System Vector Group Dyn11/Yyn0 Transformer type Dry Isolation Insulation Material Epoxy
-
50Hz Medium Voltage Dry Type Transformer 30KVA Step Up Down Instrument Transformer
50Hz Medium Voltage Dry Type Transformer 30KVA Step Up Down Instrument Transformer Product Specifications Attribute Value Type Distribution transformer Material Copper, Copper Winding Frequency 50Hz, 60Hz Shape Rectangle Winding Material Copper Application Potential Phase Three Coil Structure TOROIDAL Coil Number Multi-winding coil Input Voltage 10kV, 6kV, 6.3kV Output Voltage 0.4kV Rated Capacity 30KVA-2500KVA Cooling Method ANAF Core Material CRGO Silicon Steel Core Feature
-
3 Phase Power Transformer 800KVA 1000KVA 1250KVA Dry Type Step Up Transformer
3 Phase Power Transformer 800KVA 1000KVA 1250KVA Dry Type Step Up Transformer Product Specifications Attribute Value Type Distribution transformer, Power Isolation Transformer Frequency 50Hz, 60Hz Winding Material Aluminum Application Power Phase Three Coil Structure Layered Winding Coil Number Triple-winding coil Input Voltage 3kV, 6kV, 10kV, 15kV, 35kV, 69kV, 110kV, 220kV, 400kV, 115kV, 132kV Output Voltage 5V, 400V, 208V, 200V, 415V, 127V, 11kV, 12V, 24V, 48V, 110V, 220V,