35 KV Oil Immersed Three Phase Power Transformer 1000KVA 1600KVA for High Ambient Temperature
Three Phase Power Transformer OverviewOur 35kV oil-immersed power transformers (1000kVA / 1600kVA) are specially designed and validated for tropical and high-temperature regions, making them ideal for Africa and Latin America, where ambient temperatures, humidity, dust, and grid instability present ...
Variable Voltage 35 KV Power Transformer
,1000KVA Oil Immersed Transformer
,1600KVA Three Phase Power Transformer
Our 35kV oil-immersed power transformers (1000kVA / 1600kVA) are specially designed and validated for tropical and high-temperature regions, making them ideal for Africa and Latin America, where ambient temperatures, humidity, dust, and grid instability present significant operational challenges.
- Designed for ambient temperatures up to 45°C (optional design up to 50°C)
- Enhanced thermal margin ensures stable operation under continuous heavy load conditions
- Optimized oil circulation and radiator design improve heat dissipation in hot climates
- High-quality mineral insulating oil with excellent oxidation resistance
- Upgraded insulation materials with Class A / thermal-optimized design
- Increased creepage distance to prevent insulation aging in hot and humid environments
- Suitable for high humidity (>95%) and dusty environments common in mining and rural grid areas
- Sealed or conservator-type oil tank options reduce moisture ingress
- Breather equipped with silica gel dehydrator for effective moisture control
- Strong tolerance to frequent voltage fluctuations and unstable grid conditions
- Optional On-Load Tap Changer (OLTC) allows real-time voltage regulation without shutdown
- Reinforced winding structure improves short-circuit withstand capability in weak grids
- Multi-layer anti-corrosion coating suitable for coastal, tropical, and industrial pollution areas
- Optional C4 / C5 anti-corrosion protection for high-salinity or coastal regions
- Designed for long-term outdoor installation with minimal maintenance
- Three-phase power distribution system compatibility
- 35KV voltage rating for high-voltage applications
- Oil-immersed cooling system for optimal thermal management
- Variable voltage output capabilities
- Available in 1000KVA and 1600KVA capacity options
- Robust construction for industrial environments
- Efficient power transformation with minimal losses
| Parameter | Specification |
|---|---|
| Phase Configuration | Three Phase |
| Voltage Rating | 35KV |
| Available Capacities | 1000KVA, 1600KVA |
| Cooling System | Oil Immersed |
| Voltage Type | Variable Voltage |
| Application | Electricity Transformation |
Standard Design vs. Tropical Design
| Item | Standard Design | Tropical Design (Africa & Latin America) |
|---|---|---|
| Ambient Temperature | Up to 40°C | Up to 45°C (optional 50°C) |
| Load Capability | Rated load under normal conditions | Continuous operation under high ambient temperature & heavy load |
| Cooling System | Standard ONAN cooling | Enhanced ONAN with enlarged radiators & optimized oil circulation |
| Insulating Oil | Standard mineral oil | High-thermal-stability mineral oil with improved oxidation resistance |
| Insulation System | Standard Class A insulation | Tropicalized insulation system with higher thermal margin |
| Humidity Resistance | Normal humidity conditions | Designed for >95% relative humidity |
| Dust Protection | Standard outdoor protection | Improved sealing for dusty & mining environments |
| Oil Tank Design | Conservator type (standard) | Sealed or conservator type with upgraded breather & silica gel |
| Voltage Regulation | Off-Circuit Tap Changer (OCTC) | OCTC or On-Load Tap Changer (OLTC) |
| Grid Stability Tolerance | Normal grid conditions | Enhanced tolerance to voltage fluctuation & weak grids |
| Short-Circuit Withstand | IEC standard level | Reinforced winding structure for unstable networks |
| Anti-Corrosion Protection | Standard industrial coating | Multi-layer anti-corrosion coating (C4 / C5 optional) |
| Outdoor Installation | Normal outdoor environment | Tropical, coastal, high-salinity & polluted environments |
| Maintenance Requirement | Standard maintenance | Reduced maintenance under harsh environments |
| Service Life Expectancy | 20–25 years | 25–30 years |
| Typical Markets | Mild climate regions | Africa, Central America, South America, Caribbean |
| Initial Cost | Lower | Slightly higher |
| Total Life-Cycle Cost | Standard | Lower due to higher reliability & fewer failures |
-
Double-winding OLTC 110kV Power Transformer Trusted Solution for Long-Term Power Infrastructure
Double-winding OLTC 110kV Power Transformer - Trusted Solution for Long-Term Power Infrastructure HENTG POWER Double-winding OLTC 110kV Power Transformer offers a reliable solution for long-term power infrastructure with high reliability, strong voltage regulation capability, and optimized total ...
-
High Capacity 6000KVA 5300KVA Oil Immersed Power Transformer with 33KV High Voltage for Industrial Use
High Quality Oil Cooled 6000KVA 5300KVA Three Phase Electric Transformer 33KV 35KV 50Hz 10KVA for Electronic Our high-capacity 33kV oil-immersed power transformers are designed for industrial and utility-scale applications requiring stable power delivery under heavy loads .Available in 6000kVA and ...
-
2500kVA Oil-Immersed Power Transformer with OLTC
2500kVA/3150kVA Oil-Immersed Power Transformer with OLTC for Renewable Energy The On-Load Tap Changer (OLTC) transformer is designed for medium-voltage distribution networks requiring real-time voltage regulation under load . It is widely used in industrial parks, urban grids, and renewable energy ...