HENTG POWER 400kVA 11kV/0.4kV Three-Phase Oil-Immersed Transformer with ONAN Cooling for Commercial & Industrial Use
HENTG POWER 400kVA ナイジェリア向け油入変圧器。 11kV/0.4kV、IEC 60076準拠。波形タンクと HNBR シールが熱帯熱の漏れを防ぎます。銅巻線、Dyn11 ベクトル グループはグリッド変動に対応します。 ONAN 冷却による 1.2 倍の過負荷容量。
1. Product Brief
The HENTG POWER 400kVA oil-immersed transformer is designed for 11kV primary / 0.4kV secondary distribution in commercial complexes and industrial factory environments.
Rated at 50Hz, ONAN (Oil Natural Air Natural) cooling, this three-phase transformer meets IEC 60076 standards.
It is optimized for Nigeria’s grid conditions and tropical ambient temperatures (up to 45°C), providing reliable step-down power from 11kV medium voltage to 400V three-phase / 230V single-phase end-user supply.
2. Why Choose HENTG POWER?
-
IEC 60076-compliant core & windings – Grain-oriented silicon steel (M5 grade, 0.23mm thickness) reduces no-load loss by consistent magnetic flux density (1.65T).
-
Sealed tank design (corrugated wall) – Expansion corrugated fins absorb oil volume variation from -5°C to +55°C ambient, eliminating conservator-related leakage risks.
-
High overload capacity – ONAN cooling allows 1.2x continuous overload for 6 hours within 45°C ambient without winding hotspot exceeding 105°C (class A insulation, 220°C cellulose paper).
-
Dyn11 vector group – Handles unbalanced loads common in Nigerian commercial clusters (shops, factories with welding equipment).
-
Low noise operation – ≤55 dB(A) at 1m distance, measured per IEC 60076-10.
-
Anti-condensation treatment – HV/LV bushing sealing with NBR rubber (shore A 70±5) and hydrophobic coating on terminals for high-humidity coastal regions (Lagos, Port Harcourt).
3. Detailed Specifications & Technical Features (H2: Technical Parameters)
Core Parameters (IEC 60076-1)
-
Rated power: 400kVA
-
Primary voltage: 11kV ±2×2.5%
-
Secondary voltage: 0.4kV
-
Frequency: 50Hz
-
Vector group: Dyn11
-
Impedance voltage: 4.5% (±5%)
Construction & Materials
-
Core: Step-lap stacked, cold-rolled grain-oriented silicon steel (M5, 0.23mm).
-
LV winding: Copper foil (99.9% purity) – better short-circuit withstand than aluminum.
-
HV winding: Copper wire (F class insulation, 155°C rated).
-
Insulation paper: Thermally upgraded kraft paper (220°C melting point, permittivity 3.5).
-
Tank: 3mm steel plate, hot-dip galvanized (Zn coating ≥ 85μm) for corrosion resistance in Nigeria’s humid/saline environment.
Operating conditions
-
Altitude: ≤ 1000m (customizable for Jos Plateau via derating)
-
Ambient temperature: -5°C to +45°C
-
Humidity: ≤ 95% non-condensing
Leakage prevention engineering (for Nigeria)
-
Corrugated tank with no rubber gasket on main body (only on manhole and bushings).
-
Gaskets: HNBR (Hydrogenated Nitrile) for oil resistance, compression set ≤ 20% after 1000h at 120°C.
-
Bushing sealing torque: factory set at 25Nm ±2Nm, with dual O-ring grooves.
-
Paint system: Epoxy primer (80μm) + polyurethane topcoat (80μm) – passed salt spray test 720h (ASTM B117) with no creepage.
4. Pain Point Solution for Nigeria – Minimizing Oil Leakage Risk
Pain point (Nigeria-specific)
-
Frequent grid surges and voltage fluctuations cause internal arcing and gasket aging.
-
High ambient temperature (up to 45°C) + tropical humidity accelerate rubber seal degradation.
-
Poor road conditions during transport lead to tank weld stress cracks.
-
Local maintenance culture often lacks torque wrenches, leading to over/under-tightened bushing nuts.
Our solutions (parameter-supported)
| Pain factor | HENTG POWER design measure | Evidence / specification |
|---|---|---|
| Thermal expansion stress | Corrugated tank with pre-calculated fin volume | Oil expansion volume: 0.45L per 10°C rise for 400kVA; fin capacity = 18L reserve |
| Gasket hardening | HNBR (Hydrogenated Nitrile Butadiene Rubber) | Compression set ≤ 20% after 1000h @ 120°C; oil swell ≤ 10% in 72h (ASTM D471) |
| Weld cracking | Full-penetration robotic welding + X-ray inspection | 100% of main tank welds tested per ISO 17636; no weld repair allowed without re-X-ray |
| Over-tightening damage | Torque-limiting markings on bushing nuts | Factory marking at 25Nm; ±10% tolerance visible after installation |
| Corrosion under gasket | Zinc-rich primer + silicone sealant at joints | Salt spray resistance 720h (ASTM B117) – no red rust |
| Sand/dust ingress | IP54-rated terminal box (on request) | With optional IP54 enclosure for LV side (standard is IP44) |
Result statement (no fake %)
In internal accelerated aging tests (85°C oil temperature, 90% RH, 500h cycle), the corrugated tank and HNBR gaskets showed zero visible leakage; torque retention remained within 22-28Nm range.
5. FAQ for Nigerian Distributors & EPC Contractors
Q1: Can this transformer handle 33kV primary? We sometimes have 33kV feeders in industrial zones.
A: The standard model is 11kV primary. For 33kV applications, we offer a variant with 33kV bushings and reinforced insulation (36kV rated, BIL 170kV). Please specify voltage at order.
Q2: How do you prevent oil leakage during transport on bad roads from Lagos to Kano?
A: All HENTG POWER transformers are shipped with zero oil (dry). We use nitrogen-filled tank pressure (0.2 bar) to detect weld leaks before shipment. After installation, first oil fill is done on-site – this eliminates transit vibration leakage.
Q3: What is the standard warranty and do you have a local agent in Nigeria?
A: 24-month warranty from commissioning date or 30 months from shipment, whichever earlier. We have a technical partner in Lagos with stock of bushings, gaskets, and DGA test kits. Service response within 48 hours.
Q4: Can we use this transformer for a cold storage facility with frequent on/off cycling?
A: Yes – the Dyn11 vector group and copper winding (low thermal expansion mismatch) tolerate daily load cycles. However we recommend no more than 4 full load cycles per day to avoid cumulative insulation stress. For frequent switching (e.g., 10 cycles/day), we suggest optional load tap changer (OLTC) – consult HENTG POWER engineering.
Q5: What type of transformer oil is pre-filled? Can we use local oil?
A: Factory-filled with inhibited mineral oil (IEC 60296, grade A, breakdown voltage ≥ 60kV/2.5mm). Local oil can be used only if it meets same dielectric strength and pour point (-30°C) – we advise sending sample to our lab for compatibility test.
Q6: What grounding system do you recommend for Nigerian factories (TN-C or TT)?
A: The LV winding (0.4kV side) comes with a removable neutral link. For TN-C systems, we recommend solid neutral grounding. For TT, use the neutral link with surge arrester (MOV 275V) – not included but can be ordered as accessory.
6. Our HENTG POWER – Company & Technical Leadership
HENTG POWER specializes in medium-voltage oil-immersed transformers (50kVA to 10MVA) for emerging markets, with a dedicated engineering team for tropical and high-salinity environments.
Technical certifications
-
IEC 60076-1 to -10 compliant design (Type-tested at KEMA or equivalent independent lab)
-
ISO 9001:2015 production facility
-
Short-circuit withstand test passed: 400kVA model at 11kV, 4.5% impedance, 25 cycles (IEC 60076-5)
Key manufacturing capabilities
-
Core cutting: Silencer shear line with 0.02mm accuracy, step-lap joints.
-
Vacuum drying & oil filling: Residual moisture ≤ 0.5% in insulation (measured by Karl Fischer).
-
Pressure leak test: 0.3 bar air pressure for 12 hours – zero drop allowed.
-
Partial discharge (PD) test: ≤ 10pC at 1.1× rated voltage (IEC 60076-3).
Why Nigeria customers choose HENTG POWER
-
Every transformer shipped with individual oil sample test report (breakdown voltage, moisture, dielectric dissipation factor).
-
Customizable for 50Hz grid fluctuations (±10% voltage, ±5% frequency) – internal design margin for +15% voltage.
-
10-year spare parts availability commitment for gaskets, bushings, and cooling fins.

-
ステップアップ オイル浸水型 トランスフォーマー 125 Kva 12 Kv サブステーション パワー トランスフォーマー
ステップアップ油入変圧器 125 KVA 12 KV 変電所用電力変圧器 製品仕様 属性 値 タイプ 配電用変圧器、油入変圧器 材質 銅、アルミニウム、銅巻線 周波数 60Hz、50Hz 巻線材料 銅、アルミニウム 用途 配電システム 相 三相 定格容量 30-3000kVA 冷却 ONAN/ONAFまたはカスタマイズ 保護レベル IP00 保証 3年 製品概要 HENTG Power Step Up Transformerは、変電所用途向けに設計された高性能115kV/132kV電力変圧器です。IEC、ANSI、BSを含む国際規格に準拠しており、CEおよびISO9001認証を取得しています。 ...
-
可変電圧油入変圧器 6.3-10KV 250-630kVA 3相 多巻線
可変電圧油入変圧器 6.3-10KV 250-630kVA 3相 多巻線 製品属性 属性 値 周波数 50Hz、60Hz 巻線数 三巻線、多巻線、二巻線、単巻線 用途 配電システム 巻線構造 完全密閉構造 出力電圧 415V、110V、220V、380V、400V、440V 入力電圧 10.5kV、3kV、12.47kV、6.6kV タイプ 油入変圧器、絶縁変圧器、電圧調整器変圧器、オートトランス、現場調整可能変圧器、二巻線変圧器 技術仕様 定格容量 (KVA) ベクトルグループ 電圧組み合わせ 無負荷損失 負荷損失 インピーダンス 30 Yyn0 / Dyn11 10/6.3/6 65 ...
-
MV HV 油入変圧器 315kVA ~ 630kVA 三相配電変圧器 60Hz
MV HVオイル浸漬トランス315KVAから630KVA 3位相分布トランス60Hz 製品仕様 属性 価値 頻度 60Hz 段階 3、単相 応用 パワートランス 出力電圧 415V、380V、400V、110V、220V、440V、480V 入力電圧 11kv、10.5kv、6.3kv、6.6kv、6kv、10kv、35kv タイプ オイル浸漬トランス コイル 銅/アルミニウムコイル 使用法 電力、配布トランス 定格電力 10-5000 kVa 断熱クラス クラスA、クラスB、クラスF、クラスh 冷却 onan/onafまたはカスタマイズ 材料 銅 +アルミニウム トランスタイプ S11オイル...