HENTG POWER 400kVA 11kV/0.4kV Three-Phase Oil-Immersed Transformer with ONAN Cooling for Commercial & Industrial Use

Produktübersicht

HENTG POWER 400-kVA-Öltransformator für Nigeria. 11 kV/0,4 kV, IEC 60076-konform. Wellpappentank- und HNBR-Dichtungen verhindern Leckagen bei tropischer Hitze. Kupferwicklungen, Dyn11-Vektorgruppe bewältigen Netzschwankungen. ONAN-Kühlung für 1,2-fache Überlastfähigkeit.

Wesentliche Eigenschaften
Markenname: HENTG POWER
Modellnummer: S11-400-11/0,4
Herkunftsort: China
Zertifizierung: IEC, CE, ISO9001
Mindestbestellmenge: 1
Versorgungsfähigkeit: 300 MVA/Jahr
Lieferzeit: 25 Tage
Zahlungsbedingungen: T/T, L/C
Standardverpackung: Sperrholzkiste
Produktanpassungsattribute
Wickelmaterial:
Kupfer und Aluminium sind optional
Nennkapazität:
400KVA
Primärspannung:
11 kV ±2×2,5 %
Sekundärspannung:
0,4 kV
Produktbeschreibung

1. Product Brief

The HENTG POWER 400kVA oil-immersed transformer is designed for 11kV primary / 0.4kV secondary distribution in commercial complexes and industrial factory environments.
Rated at 50Hz, ONAN (Oil Natural Air Natural) cooling, this three-phase transformer meets IEC 60076 standards.
It is optimized for Nigeria’s grid conditions and tropical ambient temperatures (up to 45°C), providing reliable step-down power from 11kV medium voltage to 400V three-phase / 230V single-phase end-user supply.


2. Why Choose HENTG POWER?

  • IEC 60076-compliant core & windings – Grain-oriented silicon steel (M5 grade, 0.23mm thickness) reduces no-load loss by consistent magnetic flux density (1.65T).

  • Sealed tank design (corrugated wall) – Expansion corrugated fins absorb oil volume variation from -5°C to +55°C ambient, eliminating conservator-related leakage risks.

  • High overload capacity – ONAN cooling allows 1.2x continuous overload for 6 hours within 45°C ambient without winding hotspot exceeding 105°C (class A insulation, 220°C cellulose paper).

  • Dyn11 vector group – Handles unbalanced loads common in Nigerian commercial clusters (shops, factories with welding equipment).

  • Low noise operation – ≤55 dB(A) at 1m distance, measured per IEC 60076-10.

  • Anti-condensation treatment – HV/LV bushing sealing with NBR rubber (shore A 70±5) and hydrophobic coating on terminals for high-humidity coastal regions (Lagos, Port Harcourt).


3. Detailed Specifications & Technical Features (H2: Technical Parameters)

Core Parameters (IEC 60076-1)

  • Rated power: 400kVA

  • Primary voltage: 11kV ±2×2.5%

  • Secondary voltage: 0.4kV

  • Frequency: 50Hz

  • Vector group: Dyn11

  • Impedance voltage: 4.5% (±5%)

Construction & Materials

  • Core: Step-lap stacked, cold-rolled grain-oriented silicon steel (M5, 0.23mm).

  • LV winding: Copper foil (99.9% purity) – better short-circuit withstand than aluminum.

  • HV winding: Copper wire (F class insulation, 155°C rated).

  • Insulation paper: Thermally upgraded kraft paper (220°C melting point, permittivity 3.5).

  • Tank: 3mm steel plate, hot-dip galvanized (Zn coating ≥ 85μm) for corrosion resistance in Nigeria’s humid/saline environment.

Operating conditions

  • Altitude: ≤ 1000m (customizable for Jos Plateau via derating)

  • Ambient temperature: -5°C to +45°C

  • Humidity: ≤ 95% non-condensing

Leakage prevention engineering (for Nigeria)

  • Corrugated tank with no rubber gasket on main body (only on manhole and bushings).

  • Gaskets: HNBR (Hydrogenated Nitrile) for oil resistance, compression set ≤ 20% after 1000h at 120°C.

  • Bushing sealing torque: factory set at 25Nm ±2Nm, with dual O-ring grooves.

  • Paint system: Epoxy primer (80μm) + polyurethane topcoat (80μm) – passed salt spray test 720h (ASTM B117) with no creepage.


4. Pain Point Solution for Nigeria – Minimizing Oil Leakage Risk

Pain point (Nigeria-specific)

  • Frequent grid surges and voltage fluctuations cause internal arcing and gasket aging.

  • High ambient temperature (up to 45°C) + tropical humidity accelerate rubber seal degradation.

  • Poor road conditions during transport lead to tank weld stress cracks.

  • Local maintenance culture often lacks torque wrenches, leading to over/under-tightened bushing nuts.

Our solutions (parameter-supported)



Pain factor HENTG POWER design measure Evidence / specification
Thermal expansion stress Corrugated tank with pre-calculated fin volume Oil expansion volume: 0.45L per 10°C rise for 400kVA; fin capacity = 18L reserve
Gasket hardening HNBR (Hydrogenated Nitrile Butadiene Rubber) Compression set ≤ 20% after 1000h @ 120°C; oil swell ≤ 10% in 72h (ASTM D471)
Weld cracking Full-penetration robotic welding + X-ray inspection 100% of main tank welds tested per ISO 17636; no weld repair allowed without re-X-ray
Over-tightening damage Torque-limiting markings on bushing nuts Factory marking at 25Nm; ±10% tolerance visible after installation
Corrosion under gasket Zinc-rich primer + silicone sealant at joints Salt spray resistance 720h (ASTM B117) – no red rust
Sand/dust ingress IP54-rated terminal box (on request) With optional IP54 enclosure for LV side (standard is IP44)

Result statement (no fake %)
In internal accelerated aging tests (85°C oil temperature, 90% RH, 500h cycle), the corrugated tank and HNBR gaskets showed zero visible leakage; torque retention remained within 22-28Nm range.


5. FAQ for Nigerian Distributors & EPC Contractors

Q1: Can this transformer handle 33kV primary? We sometimes have 33kV feeders in industrial zones.
A: The standard model is 11kV primary. For 33kV applications, we offer a variant with 33kV bushings and reinforced insulation (36kV rated, BIL 170kV). Please specify voltage at order.

Q2: How do you prevent oil leakage during transport on bad roads from Lagos to Kano?
A: All HENTG POWER transformers are shipped with zero oil (dry). We use nitrogen-filled tank pressure (0.2 bar) to detect weld leaks before shipment. After installation, first oil fill is done on-site – this eliminates transit vibration leakage.

Q3: What is the standard warranty and do you have a local agent in Nigeria?
A: 24-month warranty from commissioning date or 30 months from shipment, whichever earlier. We have a technical partner in Lagos with stock of bushings, gaskets, and DGA test kits. Service response within 48 hours.

Q4: Can we use this transformer for a cold storage facility with frequent on/off cycling?
A: Yes – the Dyn11 vector group and copper winding (low thermal expansion mismatch) tolerate daily load cycles. However we recommend no more than 4 full load cycles per day to avoid cumulative insulation stress. For frequent switching (e.g., 10 cycles/day), we suggest optional load tap changer (OLTC) – consult HENTG POWER engineering.

Q5: What type of transformer oil is pre-filled? Can we use local oil?
A: Factory-filled with inhibited mineral oil (IEC 60296, grade A, breakdown voltage ≥ 60kV/2.5mm). Local oil can be used only if it meets same dielectric strength and pour point (-30°C) – we advise sending sample to our lab for compatibility test.

Q6: What grounding system do you recommend for Nigerian factories (TN-C or TT)?
A: The LV winding (0.4kV side) comes with a removable neutral link. For TN-C systems, we recommend solid neutral grounding. For TT, use the neutral link with surge arrester (MOV 275V) – not included but can be ordered as accessory.


6. Our HENTG POWER – Company & Technical Leadership

HENTG POWER specializes in medium-voltage oil-immersed transformers (50kVA to 10MVA) for emerging markets, with a dedicated engineering team for tropical and high-salinity environments.

Technical certifications

  • IEC 60076-1 to -10 compliant design (Type-tested at KEMA or equivalent independent lab)

  • ISO 9001:2015 production facility

  • Short-circuit withstand test passed: 400kVA model at 11kV, 4.5% impedance, 25 cycles (IEC 60076-5)

Key manufacturing capabilities

  • Core cutting: Silencer shear line with 0.02mm accuracy, step-lap joints.

  • Vacuum drying & oil filling: Residual moisture ≤ 0.5% in insulation (measured by Karl Fischer).

  • Pressure leak test: 0.3 bar air pressure for 12 hours – zero drop allowed.

  • Partial discharge (PD) test: ≤ 10pC at 1.1× rated voltage (IEC 60076-3).

Why Nigeria customers choose HENTG POWER

  • Every transformer shipped with individual oil sample test report (breakdown voltage, moisture, dielectric dissipation factor).

  • Customizable for 50Hz grid fluctuations (±10% voltage, ±5% frequency) – internal design margin for +15% voltage.

  • 10-year spare parts availability commitment for gaskets, bushings, and cooling fins.