Explosion-Proof Mining Transformer for Underground Coal Mines Ex Certified
Explosion-Proof Mining Transformer for Underground Coal Mines Ex Certified Our explosion-proof mining transformers are engineered specifically for underground safety in hazardous mining environments. These mining flameproof substations are designed for special and harsh environmental conditions with excellent explosion-proof performance and mechanical strength. Safety & Performance Features 220°C insulation class for high-temperature operation Flameproof Group IIB, Zone 1,
explosion-proof mining transformer
,Ex certified coal mine transformer
,dry type mining transformer
- 220°C insulation class for high-temperature operation
- Flameproof Group IIB, Zone 1, Zone 2 certification
- Fire-proof construction with non-toxic air creation
- Low noise operation and environmentally protected design
- Maintenance-free operation with heat shock resistance
- Superior overload capacity and multiple protective functions
- Protection against overload, short circuit, leakage, leakage lockout, over-voltage, under-voltage and over temperature
- Certified MA & Explosion-Proof (Ex) compliance
- Explosion-proof enclosure with robust mechanical protection
- Resistant to humidity, dust, corrosion and vibration
- High reliability and low maintenance for continuous operation
- Suitable for underground conveyors, pumps, lighting & ventilation systems
- Compact structure for narrow mine shafts; mobile and fixed options available
| Parameter | Specification |
|---|---|
| Transformer Type | Dry type |
| Rated Capacity | Up to 8000kVA |
| Rated Voltage | Up to 11kV |
| Frequency | 50/60Hz |
| Phase | 3 Phase |
| Winding Material | Copper / Aluminum |
| Insulation Class | H(180℃), C (220℃) |
| Vector Group | Dyn11, YNd1d1 |
| Cooling | ANAN, GNAN |
| Protection Enclosure | IP00 to IP54 |
| Explosion-proof Type | ExdIMb |
| Zone | Zone 1, Zone 2 |
| Tank Painting | C4 and C5 on request |
| Altitude | Max 2300m |
| Standard | IEC, AS, EN, IEEE/ANSI, GOST |
- Mining Flameproof HV vacuum switch + Mining Flameproof LV protection box
- Mining Flameproof HV vacuum switch + Mining Flameproof LV feed switch
- Mining Flameproof HV vacuum switch + Mining Flameproof LV multi-loop combined switch (LMCC)
-
Epoxy Resin Dry Type Distribution Transformer 80 Kva 3 Phase With Triple Winding Coil
Epoxy Resin Dry Type Distribution Transformer 80 Kva 3 Phase With Triple Winding Coil Product Specifications Attribute Value Type Power transformer, distribution transformer, Dry Type Transformer Frequency 50Hz, 60Hz Winding Material Copper Application Power Phase Three Coil Structure Layered Winding Coil Number Triple-winding coil Input Voltage 10kV Output Voltage 400V Cooling Method Fan System Vector Group Dyn11/Yyn0 Transformer type Dry Isolation Insulation Material Epoxy
-
50Hz Medium Voltage Dry Type Transformer 30KVA Step Up Down Instrument Transformer
50Hz Medium Voltage Dry Type Transformer 30KVA Step Up Down Instrument Transformer Product Specifications Attribute Value Type Distribution transformer Material Copper, Copper Winding Frequency 50Hz, 60Hz Shape Rectangle Winding Material Copper Application Potential Phase Three Coil Structure TOROIDAL Coil Number Multi-winding coil Input Voltage 10kV, 6kV, 6.3kV Output Voltage 0.4kV Rated Capacity 30KVA-2500KVA Cooling Method ANAF Core Material CRGO Silicon Steel Core Feature
-
3 Phase Power Transformer 800KVA 1000KVA 1250KVA Dry Type Step Up Transformer
3 Phase Power Transformer 800KVA 1000KVA 1250KVA Dry Type Step Up Transformer Product Specifications Attribute Value Type Distribution transformer, Power Isolation Transformer Frequency 50Hz, 60Hz Winding Material Aluminum Application Power Phase Three Coil Structure Layered Winding Coil Number Triple-winding coil Input Voltage 3kV, 6kV, 10kV, 15kV, 35kV, 69kV, 110kV, 220kV, 400kV, 115kV, 132kV Output Voltage 5V, 400V, 208V, 200V, 415V, 127V, 11kV, 12V, 24V, 48V, 110V, 220V,