Low-Noise 200kVA Compact Ring Main Unit Substation Transformer – IEC Residential Power Distribution
Düşük gürültülü 200kVA kompakt RMU trafo merkezi, transformatörü ve SF6 şalt sistemini kurcalamaya dayanıklı tek bir muhafazada birleştirir. Hermetik olarak kapatılmış yağ deposu, düşük kayıplı IEC 60076 tasarımı ve fabrikada ön işletmeye alma özelliklerine sahiptir. Sıkı gürültü düzenlemelerine ve sınırlı alan gereksinimlerine sahip yerleşim alanları için idealdir.
The low-noise 200kVA Compact Ring Main Unit (RMU) Substation is a fully integrated, factory-built power distribution package designed for residential pockets, quiet suburban communities, and rural electrification networks where sound sensitivity matters. This space-efficient unit combines a hermetically sealed oil-immersed distribution transformer with a three-way SF6 gas-insulated ring main unit, all housed inside a single, tamper-resistant metal enclosure. Meeting IEC 62271-202 and IEC 60076 standards, it steps medium voltage down to safe low-voltage levels and delivers reliable three-phase power precisely where it is needed, while keeping land use, on-site labor, and long-term maintenance to an absolute minimum.
- Superior Acoustic Comfort for Residential Areas: Core and coil assembly are specifically engineered for low magnetostriction, achieving operational sound levels that comfortably meet strict urban neighborhood noise regulations.
- Optimized Space-Saving Design: Integrates transformer and switchgear into one enclosure, requiring approximately 60% less ground space than a conventional kiosk substation — ideal for townhouse complexes, small villa communities, and rural villages.
- Truly Maintenance-Free Construction: Hermetically sealed oil tank eliminates air and moisture ingress, while the sealed-for-life SF6 RMU requires no gas refilling or internal servicing under normal conditions.
- Grid-Ready and Pre-Commissioned: Fully assembled, wired, and type-tested in the factory before shipping. On-site work is limited to placing the unit, making cable terminations, and energizing.
- Global IEC Compliance for EPCs: Complete type-test documentation simplifies approval processes for engineering, procurement, and construction (EPC) contractors and local utility providers.
| Rated Capacity | 200 kVA (ONAN self-cooled) |
|---|---|
| High Voltage | 6.6 kV, 11 kV, or customizable up to 12 kV, with off-circuit tap changer (±2×2.5%) |
| Low Voltage | 400/230 V, three-phase four-wire |
| Vector Group | Dyn11 (standard) |
| Frequency | 50/60 Hz |
| Cooling | Oil Natural Air Natural (ONAN) via corrugated tank fins |
| Tank Design | Hermetically sealed, fully oil-filled with elastic corrugated fins for thermal expansion — no conservator or silica gel breather needed |
| Dielectric Fluid | Mineral oil (natural ester fluid available for environmentally sensitive locations) |
| Efficiency | Low-loss core and winding design compliant with IEC 60076 energy performance requirements |
| Type | SF6 gas-insulated, sealed pressure system |
|---|---|
| Configuration | 2 incoming cable feeders + 1 transformer protection feeder (standard 3-way); 4-way option available |
| Rated Voltage | 12 kV / 24 kV |
| Busbar Rated Current | 630 A |
| Transformer Feeder Protection | DIN-type HV HRC fuse combination (appropriately rated fuses for 200 kVA) or vacuum circuit breaker with digital relay |
| Internal Arc Classification | IAC AFL (optional) for enhanced operator safety |
| Gas Monitoring | Integrated pressure gauge with low-pressure alarm contact interface |
| Enclosure Material | 2 mm galvanized sheet steel with anti-corrosion polyester powder coating |
|---|---|
| Ingress Protection | IP54 for transformer and switchgear compartments; IP44 for ventilation with rodent-proof stainless steel mesh |
| Approximate Dimensions | 1800 mm (L) × 1100 mm (W) × 1600 mm (H) |
| Approximate Total Mass | 1,800 kg (transport weight, including oil and RMU) |
| LV Cabinet Integration | Provision for main MCCB, CT-operated metering, and anti-condensation heater |
| Safety Earthing | Continuous copper earth bar with dual external earth terminals |
- Tight Plot Boundaries in Suburban Projects: The compact enclosure needs a foundation of only about 2000 mm × 1300 mm, fitting neatly into a small utility corner or beside a perimeter wall without disrupting landscaping.
- Stringent Community Noise Limits: Low-vibration core design and optional acoustic lining keep operational noise at or below 42 dB(A), enabling installation near residential units without complaints.
- Full Public Safety Assurance: The IP54 sealed cabinet and internal arc-rated RMU ensure no exposed live parts. Transformer overcurrent protection via the fuse combination disconnects faults in milliseconds, preventing any external hazard.
- Visual Harmony with Surroundings: The unit can be painted in custom RAL colors to match building exteriors or blend into natural environments. A sealed oil containment tray is built in to prevent any liquid leakage into the soil.
- Reliable Supply via Ring Network: The RMU supports an open-ring residential network topology. In case of a cable fault, network reconfiguration restores supply quickly, and the standard plug-in bushing design simplifies testing and cable connection.
A: Only a simple flat concrete pad of about 2000 mm × 1300 mm is required, along with prepared underground cable entries. We supply a detailed civil foundation drawing and pre-positioned cable gland plate to guide your contractor.
A: Yes. The low-voltage cabinet can be divided into separate lockable compartments for the utility's kWh meter, CTs, and the customer's incoming breaker, meeting most utility segregation requirements.
A: Absolutely. The RMU can be equipped with motor-operated disconnectors and an RTU interface. The transformer can include temperature sensors linked to an alarm loop, allowing full remote condition monitoring.
A: By sealing the tank completely, no outside air or moisture can enter the oil, preventing oxidation and sludge formation. Combined with the maintenance-free SF6 RMU, only annual visual inspections of gauges, enclosure, and ventilation are recommended.
A: The standard unit operates below 45 dB(A) at full load. We achieve this through high-grade grain-oriented silicon steel, step-lap core joints, and internal vibration dampening pads. For noise-critical projects, an enhanced acoustic insulation package is available.
A: After drawing approval, the standard manufacturing lead time is 8 to 10 weeks. We also offer expedited production slots for urgent projects. On-site supervision and cold commissioning support are available as a service add-on.
-
500kVA Kompakt Trafo Merkezi Transformatörü Elektrik Gerilim Transformatörü Geri Beslemeli Topoloji İle
500kVA Kompakt Alt İstasyon Transformörü Flyback Topoloji ile Elektrik Voltaj Transformörü Ürün Özellikleri Özellik Değer Türü Güç transformatörü, dağıtım transformatörü, Avrupa Kutusu Tipi Alt İstasyonu Malzeme Alüminyum, Bakır, Bakır sargısı Sıklık 50Hz, 60Hz. Şekli düz, dikdörtgen Topoloji Uçmak, ...
-
3 Fazlı Kompakt Alt İstasyon Transformörü Step Down Voltage Transformörü Dönüştürme Kanıtı
3 Fazlı Kompakt Alt İstasyon Transformörü Step Down Voltage Transformörü Dönüştürme Kanıtı Ürün Genel Görünümü ZGS Tipi Kombine Alt İstasyon, konut, ticari ve kamu hizmetleri ağlarında dış mekan kurulumları için idealdir.Tamamen mühürlenmiş ve yağla batırılmış, güvenli, alan tasarrufu yapan güç dağ...
-
Kompakt Alt İstasyon Orta Voltajlı Transformör 3 Faza 250kVA 500kVA 630kVA
Kompakt Trafo Merkezi Orta Gerilim Transformatörü 3 Fazlı Aşağı Yönlü 250kVA 500kVA 630kVA Ürün Özellikleri Özellik Değer Tip Dağıtım transformatörü Malzeme Alüminyum, Bakır Frekans 50Hz, 60Hz Şekil Dikdörtgen Sargı Malzemesi Alüminyum, Bakır Uygulama Güç Faz Üç Bobin Yapısı Dairesel bobin Bobin Say...