Three Phase Voltage Regulator With OLTC And 10kV 11kV 1000KVA Boosting For Industrial Substations Factory Networks And Power Systems

Product Summary

HENTG POWER three-phase OLTC voltage regulators deliver ±30% on-load automatic regulation for 6-35kV networks, with industrial-grade IEC61000-4 anti-interference control, independent OLTC tank, and 1000-10000kVA customizable capacity. Copper windings, sealed corrugated tank, GB1094/IEC compliant, ideal for substations, industrial parks, and renewable plants.

Key Attributes
Brand Name: HENTG POWER
Place of Origin: CHINA JIANGSU
Certification: IEC, CE
Product Custom Attributes
Highlight

Three phase voltage regulator OLTC

,

10kV 11kV 1000KVA boosting regulator

,

Distribution voltage regulator industrial substations

Rated System Voltage:
11kV
Output Voltage:
220 V, 440 V, 380 V, 415V
Operatingfrequency:
50 Hz Or 60 Hz
Frequency:
50 Hz Or 60 Hz
Tapchangertype:
On-load Tap Changer
Phase:
Three-phase
Product Name:
Distribution Voltage Regulators
Material:
Copper Windings, Steel Core
Tap Positions:
32
Hs Code:
85042100
Regulation:
±10%
Current Rating:
100 A To 600 A
Input Voltage:
6.6 KV, 11 KV, 12.47 KV
Voltagerange:
2.4 KV To 34.5 KV
Rated Voltage:
6kV, 10kV, 11kV, 35kV
Rated Capacity:
1000kVA To 10000kVA
Voltage Regulation Range:
-30% To +30%
Cooling Method:
Oil-immersed Self-cooling (ONAN)
Tap Steps:
7 Or 9 Taps
Measurement Accuracy:
5%
Product Description
Introduction

The HENTG POWER on-load automatic voltage regulator is a high-performance oil-immersed voltage stabilization equipment built for high-voltage power distribution networks. It adopts separated on-load tap changer (OLTC) tank and autotransformer main tank design, supporting automatic voltage adjustment within ±30% input fluctuation. This high voltage stabilizer stabilizes grid voltage continuously without power cut, protects downstream electrical assets from voltage sags and surges. It is widely deployed in power distribution lines, mining zones, industrial parks, renewable power plants, substations and remote rural power grids.

HENTG POWER provides customizable voltage regulators from 1000kVA up to 10000kVA for 6kV,10kV,11kV,35kV voltage classes. All units follow GB1094 power transformer standards and IEC anti-interference specifications, reliable for harsh outdoor and heavy industrial environments.

Core Features

✅ ±30% Wide On-Load Automatic Voltage Regulation Real-time on-load tap adjustment within -30% ~ +30% voltage fluctuation range; regulation range can be fine-tuned on site according to actual grid conditions.

✅ Industrial Grade Control Chip, Strong Anti-Interference Performance Equipped with industrial-grade control processor, stable and secure operation. Complies with IEC61000-4 EMC standard, works reliably in dusty, humid, high-electromagnetic interference harsh sites.

✅ Tap Position & Operation Counter Display with Limit Lock Protection Controller shows current tap position and total tap switching cycles. High & low tap limit protection prevents tap changer jamming and mechanical failure.

✅ Independent Tank Design for OLTC & Transformer Main Body The on-load tap changer oil tank is fully isolated from the autotransformer tank. This structure delivers higher voltage regulation accuracy and reduces cross-contamination of insulating oil.

✅ Overvoltage & Undervoltage Lockout Protection Built-in overvoltage, undervoltage protection with automatic interlock function to guarantee safe OLTC switching and avoid misoperation damage.

✅ Fully Adjustable Operation Parameters On Site Field engineers can modify voltage setpoint, action delay, allowable voltage deviation, switching cycle limit and other parameters directly on the controller panel.

✅ Sealed Corrugated Oil Tank, Safe Oil Monitoring Full-sealed corrugated oil tank structure, fitted with oil temperature indicator and pressure relief valve, safe for long-term outdoor running.

✅ Compact, Low Loss, Customizable & Easy Installation Small footprint, large rated capacity, lightweight design and low no-load & load loss. Custom dimensions and parameters available to match site layout requirements for fast installation.

Main Technical Parameters
Item Specification
Rated Voltage 6kV, 10kV, 11kV, 35kV
Rated Capacity 1000kVA,1250kVA,1600kVA,2000kVA,2500kVA,3150kVA,4000kVA,5000kVA,8000kVA,10000kVA, custom capacity available
Rated Frequency 50Hz / 60Hz
Phase 3 Phase
Cooling Method Oil-immersed Self-cooling (ONAN)
Connection Type 3-phase 3-wire Star Connection
Tap Steps 7 taps or 9 taps
Voltage Regulation Range -30% ~ +30% (adjustable on request)
Automatic Controller Parameters
Item Specification
Control Power Supply AC/DC 100~265V
Rated Power 20W
Frequency 50/60Hz
Analog Input 2 channels of 0~250V voltage input
Digital Input 17 channels switch input
Digital Output 6 channels switch output
Measurement Accuracy 5%
EMC Anti-interference Level IEC61000-4 compliant
Oil-Immersed On-Load Tap Changer (OLTC) Parameters

表格

Item Specification
Contact Resistance <500μΩ (varies with tap stages)
One Full Electric Switching Time 10s
Transition Resistance Switch Time 15 ~ 24ms
Electrical Service Life (rated capacity) >50,000 operations
Mechanical Service Life >500,000 operations
Transition Mode Single resistance or double resistance
Factory Routine Test Items (GB1094 Standard)
  1. Winding Resistance Measurement (GB1094.1)
  2. Short-Circuit Impedance & Load Loss Test (GB1094.1)
  3. No-Load Current & No-Load Loss Test (GB1094.1)
  4. Winding-to-Ground Insulation Resistance Test
  5. Insulation Routine Test (GB1094.3)
  6. Voltage Ratio Test (GB1094.1)
  7. Insulating Oil Test (GB1094.1)
  8. Full Function Test
Installation & Grounding Instructions
  1. Equipment installation is undertaken by the buyer. HENTG POWER can arrange after-sales technicians to provide on-site installation guidance.
  2. Multi-point grounding is required after equipment positioning. Grounding resistance shall not exceed 4Ω. Grounding electrode depth and construction must comply with local power industry grounding codes.
Application Scenarios
  • High voltage power distribution lines
  • Mining & quarry power supply
  • Heavy industrial manufacturing plants
  • Solar / wind renewable energy power stations
  • Rural & remote power grid renovation
  • Substation voltage stabilization system
  • Large construction site temporary high-voltage power supply
Why Choose HENTG POWER

HENTG POWER is a professional manufacturer of high voltage transformers and on-load voltage regulators. We deliver customized OLTC voltage stabilizers with strict quality control, full factory testing, long service life and reliable global after-sales support. Our regulators solve grid voltage fluctuation problems and protect your expensive high-voltage equipment.

Contact Us

For quotation, technical drawing, custom solution and lead time inquiry, please email us: 📩 info@hentgpower.com Website: https://www.hentgpower.com

  • Automatic Oil Immersed Single Phase Step Voltage Regulator 250kVA 6.6kV 7.2kV11kV for Distribution Network Voltage Stabilization

    250kVA automatic oil immersed single phase step voltage regulator for 6.6kV/7.2kV/11kV distribution networks. Features automatic voltage regulation, oil immersed cooling, and protection against overvoltage/undervoltage/overcurrent. Ideal for stabilizing voltage in utility, industrial, and rural electrification applications.

  • Quality 33kV Automatic Line Voltage Regulator | HENTG POWER factory
    VIDEO

    33kV Automatic Line Voltage Regulator | HENTG POWER

    HENTG POWER 33kV Automatic Line Voltage Regulator Product Overview The HENTG POWER 33kV Automatic Line Voltage Regulator is designed to stabilize voltage in medium-voltage distribution networks affected by long feeders, load fluctuations, and renewable energy integration. Using an on-load tap...

  • Single Phase Automatic Step Voltage Regulator AVR 13.8KV

    13.8kV Single-Phase Automatic Step Voltage Regulator with 32 tap positions, ±10% regulation range, and programmable digital controller. Suitable for pole-mounted, pad-mounted, or substation installation in industrial and mining applications. Features automatic on-load voltage regulation and supports 50/60Hz operation.

Contact Us
You Can Contact Us At Anytime!