Hermetically Sealed Oil Immersed Step-Up Transformer for Utility Scale Solar PV Power Plant Connection 20kV to 0.4kV 1250kVA

Ürün Özetleri

HENTG POWER 1250kVA 20kV/0.4kV şebeke ölçekli PV tesisleri, BESS ve hidroelektrik entegrasyonu için tasarlanmış endüstriyel kademeli artırıcı yağlı transformatör. Sızıntı risklerini en aza indirmek için hava geçirmez şekilde kapatılmış yapıya sahiptir.

Anahtar Nitelikler
Marka Adı: HENTG POWER
Model Numarası: S11-1250/20
Menşe Yeri: Çin
Sertifikasyon: CE
Adedi: 1
Tedarik Yeteneği: 5
Teslimat süresi: 35
Ödeme Koşulları: L/C,D/A,D/P,T/T,Western Union
Standart paketleme: tahta sandık
Ürün Özel Nitelikleri
Vurgulamak

Utility Scale Step-Up Transformer

,

Oil Immersed Step-Up Transformer

,

1250kVA Step-Up Transformer

Ürün adı:
Aşama transformatör
Sıklık:
50/60 Hz
Başvuru:
Güç Dağıtım Sistemi Güç Transformatörü
Nominal kapasite:
1250kva
yüksek voltaj:
20kv
Alçak Gerilim:
400V
soğutma yöntemi:
Onan onaf
Empedans voltajı:
% 6
Ürün Açıklaması
Hermetically Sealed Oil Immersed Step-Up Transformer for Utility Scale Solar PV Power Plant Connection 20kV to 0.4kV  1250kVA 0
1. Product Overview

The HENTG POWER 1250kVA 20kV/0.4kV three-phase step-up transformer is an industrial oil-immersed power distribution solution engineered for medium-voltage utility applications. It is designed to convert low-voltage (0.4kV) generation input to medium-voltage (20kV) grid-level output, supporting applications in renewable energy integration, battery energy storage systems (BESS), and hydroelectric facilities. The unit features a robust hermetically sealed tank filled with high-grade mineral oil, providing stable dielectric strength and thermal performance. It is manufactured in accordance with international standards for power transformers to support reliable operation in outdoor and substation environments.

2. Product Highlights
  • Enhanced Sealed Tank Design:

    Features a fully welded, hermetically sealed tank construction with reinforced corrugated fins. This configuration reduces the reliance on traditional conservator breathing and helps limit the potential for oil spillage—an important consideration for ecological zones near hydro plants and solar farms.

  • Efficient Core Performance:

    Constructed with grain-oriented silicon steel cores to support reduced no-load losses and hysteresis. This contributes to improved overall efficiency and helps lower operational expenditure for EPC and utility operators.

  • Optimized for Step-Up Duty:

    The winding configuration is calculated to accommodate the harmonic and inrush current characteristics associated with PV inverters and BESS power conversion systems (PCS), supporting stable voltage regulation from 0.4kV to 20kV.

  • Durable External Protection:

    Surface treatment includes anti-corrosion primer and polyurethane topcoat suitable for C4/C5-I environmental conditions, helping to extend service life in coastal hydropower sites and high-humidity solar PV fields.

  • Flexible Monitoring Integration:

    Equipped with standard pockets for a dial thermometer, liquid level gauge, and pressure relief device. Optional ports are available for PT100 temperature sensors and Buchholz relay integration to support SCADA monitoring in unmanned substations.

3. Technical Specifications & Construction Details

This HENTG POWER oil-immersed transformer incorporates engineering details suitable for modern power infrastructure requirements.

Category Parameter / Feature
Model Reference HENTG-S11-1250/20-0.4 Step Up
Capacity 1250 kVA (ONAN Cooling)
Primary Voltage (HV Side) 20 kV (Step-Up Output)
Secondary Voltage (LV Side) 0.4 kV (Input from Inverter/PCS)
Vector Group Dyn11 or YNd11
Frequency 50Hz / 60Hz Configurable
Cooling Method ONAN (Oil Natural Air Natural)
Tank Design Hermetically Sealed Corrugated Tank
Insulation Liquid Mineral Oil (PCB-Free) with High Dielectric Breakdown Voltage (>50kV)
Core Material Cold Rolled Grain Oriented (CRGO) Silicon Steel, Step-Lap Joint Design
Winding Material Electrolytic Grade Copper (Cu) or Aluminum (Al) with thermally upgraded paper insulation
Tap Changer Off-Circuit Tap Changer (OCTC) on HV side, ±2x2.5% or ±5% Range
Terminal Arrangement Sidewall bushings for 20kV (Porcelain/Composite) and 0.4kV (Porcelain)
4. Application & Scenario Solutions

Target Environments: PV Power Plant, BESS, Hydro Power Station

Scenario Technical Consideration HENTG POWER Design Approach
Utility-Scale PV Farm Solar inverters output at low voltage (400V) and are located in open, dusty areas. Traditional transformer designs may allow moisture ingress over time. Hermetically Sealed Corrugated Fins: The tank is completely sealed from the atmosphere. Corrugated walls flex to accommodate oil thermal expansion, reducing the air-oil interface. Result: Helps reduce routine oil maintenance and supports site cleanliness in solar arrays.
BESS Substation BESS requires bidirectional power flow. Transformers need to manage load fluctuations and potential reverse power flow. Electromagnetic Design for Inverter Duty: Winding insulation is reinforced to handle harmonic distortion and switching transients from PCS systems. The welded tank cover helps avoid gasket fatigue under cyclical thermal stress.
Small to Medium Hydro Station High humidity and proximity to water increase corrosion potential. Environmental guidelines restrict oil leakage. Heavy-Duty Corrosion Protection: Tank exterior undergoes preparation to SA 2.5 standards and receives a multi-layer coating. Double-sealed bushing gaskets and leak-tested weld seams support a closed system suitable for sensitive ecological areas.
5. Frequently Asked Questions
Q1: Is this step-up transformer suitable for connection to a Solar PV inverter with a 400V AC output?
A: Yes. The 0.4kV low-voltage winding is rated to accept the AC output from utility-scale central inverters or string inverter combiner boxes. The 20kV output is designed to match standard medium-voltage collector grids. Confirming the vector group (Dyn11) with your EPC is recommended to ensure alignment with the inverter's configuration.
Q2: We are an EPC company installing a BESS site. How does this transformer handle the fluctuating load profile of a battery storage system?
A: This unit is designed for continuous duty at rated load and can accommodate short-term overloads typical of BESS peak shaving. The ONAN cooling and oil volume provide a thermal time constant suitable for absorbing cyclical heat from charging/discharging cycles, helping to maintain stable internal pressure and extend gasket service life.
Q3: We are a utility company concerned about environmental compliance near a hydropower dam. What measures help limit oil leakage risk?
A: The HENTG POWER design utilizes a Hermetically Sealed Corrugated Tank. The tank is welded shut after oil filling under vacuum, and there is no vent to atmosphere. HV and LV bushings use Nitrile (NBR) gaskets resistant to ozone and water. An optional spill containment bund can be integrated into the base skid upon request.
Q4: I am a distributor. What is the typical lead time and applicable standards?
A: Standard lead time is 30-45 days depending on customization. This unit is manufactured and tested according to IEC 60076 (Power Transformers) and ANSI/IEEE C57.12.00 standards. A Factory Acceptance Test (FAT) report is provided.
Q5: Can this transformer operate in high-altitude solar farms (above 2000m)?
A: Yes. For installations above 1000m altitude, we apply a derating factor to the cooling capacity and adjust external creepage distances on the 20kV bushings. Please specify the exact altitude during inquiry so we can adjust the bushing selection and internal insulation clearances accordingly.
Q6: What is the recommended protective relay scheme for this 1250kVA step-up transformer?
A: For the 20kV side, an overcurrent and earth fault protection scheme (50/51/50N) is typically recommended. Since the unit is oil-immersed, integrating the optional Buchholz Relay (gas and oil surge detection) and Winding Temperature Indicator (WTI) contacts into the tripping circuit is suggested to provide early warning of internal conditions.