HENTG POWER 33kV 2.5MVA Zig-Zag transformer for wind farm collector substations
HENTG POWER 33kV Zig-Zag transformers provide reliable neutral grounding for wind farm collector networks. Featuring optimized zero-sequence impedance, Class F insulation, and customizable corrosion-resistant designs, they ensure efficient earth fault protection and durability in harsh environments.
33kV Zig-Zag transformer
,2.5MVA wind farm transformer
,collector substation transformer
HENTG POWER 33kV 2.5MVA Zig-Zag Transformer for Wind Farm Collector Substations
Zig-Zag Grounding Transformer for Wind Turbine MV Collector Cable Networks
Product Overview
HENTG POWER Zig-Zag Transformers are engineered for wind farm medium-voltage collector systems, providing an artificial neutral point and supporting reliable earth fault protection across wind turbine feeder networks.
Large wind farms typically use extensive underground MV cable networks, multiple turbine step-up transformers and centralized collector substations. These arrangements require careful grounding coordination to manage capacitive earth fault currents and transient overvoltages.
Our Zig-Zag Transformers are customized to meet the electrical and environmental requirements of onshore and coastal wind energy projects.
Product Highlights
Wind Farm Collector System Compatibility
Designed for centralized renewable energy substations of onshore wind projects.
Optimized Zero-Sequence Impedance
Supports coordinated ground fault current distribution across feeder networks.
Cable Network Grounding Support
Suitable for grounding arrangements involving extensive MV underground cable feeders.
Harsh Environment Adaptability
Optional high-altitude, coastal and corrosion-resistant designs for tough site conditions.
Reliable Short-Time Fault Withstand
Thermal and mechanical designs based on specified grounding duty and fault duration.
Technical Design Features
| Technical Item | Design Description |
|---|---|
| Rated Voltage | 33kV, with alternative MV voltage classes available |
| Reference Capacity | 2.5MVA, subject to project grounding calculations |
| Vector Connection | ZN |
| Neutral Terminal | Accessible and insulated for the selected grounding arrangement |
| Zero-Sequence Impedance | Designed according to collector network requirements |
| Cable Charging Current | Considered during grounding system selection |
| Earth Fault Withstand | Specified neutral current and fault clearing duration |
| Tank Protection | Customized anti-corrosion coating system |
| Insulating Medium | Mineral insulating oil or approved alternative upon request |
| Installation Conditions | Outdoor, coastal, high-altitude or dusty environments |
The winding structure is designed to provide a controlled zero-sequence current path during single-phase earth faults.
For wind farms with long underground cable feeders, the total phase-to-earth capacitance can significantly influence the grounding current. Therefore, cable lengths, cable types, operating feeder configurations and protection settings should be reviewed before finalizing transformer impedance and grounding equipment.
For coastal projects, enclosure sealing, terminal insulation, surface creepage distance and protective coating systems can be adapted to the environmental specification.
Wind Farm Collector Grounding Solution
Typical system arrangement: Wind Turbine Generators → Turbine Step-Up Transformers → 33kV Collector Bus → Main Power Transformer → Utility Grid
The Zig-Zag Transformer is connected as a grounding branch to the collector bus, with its neutral connected to the selected grounding equipment.
HENTG POWER supports EPC contractors in evaluating centralized or sectionalized collector bus grounding arrangements. Depending on the network design, the solution may incorporate resistance grounding or resonant grounding to address cable-related earth fault characteristics.
This approach is particularly relevant for African wind energy projects involving remote installation sites, long feeder distances and demanding maintenance conditions.
Frequently Asked Questions
Q1: Why are Zig-Zag Transformers used in wind farms?
A: They provide a neutral grounding point for collector networks that do not have an accessible system neutral.
Q2: Does the total length of underground cables affect transformer selection?
A: Yes. Cable capacitance influences earth fault current and must be considered when selecting the grounding arrangement.
Q3: Can one transformer serve multiple wind turbine feeders?
A: Yes, provided the feeders belong to the same electrically connected grounding zone and the arrangement is validated by the system study.
Q4: Can the transformer be installed in coastal African regions?
A: Yes. Corrosion protection, creepage distance and enclosure design can be customized according to the site's environmental conditions.
Q5: Can we request a customized tank size for transportation to remote sites?
A: Transportation restrictions and installation dimensions can be evaluated during the mechanical design stage.
Q6: What documents are available for EPC technical approval?
A: Customized datasheets, general arrangement drawings, terminal diagrams, technical compliance schedules and agreed testing documentation.
Request Wind Farm Grounding Design
Contact HENTG POWER for a reliable wind farm collector system grounding design.
Email: info@hentgpower.com
Send InquiryHENTG POWER — Power Transformation · Smarter Distribution
-
33kV Grounding Transformer for Grid-Connected Battery Energy Storage Systems
HENTG POWER 33kV zig-zag grounding transformers deliver reliable neutral grounding and earth fault protection for grid-connected BESS and hybrid storage networks. Engineered for controlled fault current, flexible station integration, and customized PCS coordination, they support safe charging, discharging, and islanded modes. Ideal for African EPC projects seeking certified, customizable MV grounding solutions.
-
Excellent SG-30KVA 220V To 380V Three-Phase Dry Type Auto Transformer
The SG-30KVA 220V to 380V Three-Phase Dry Type Autotransformer is a high-performance, energy-efficient solution designed for industrial and commercial applications. This transformer offers reliable voltage conversion from 220V to 380V, providing stable and consistent power
-
High Quality SG-80KVA 400/400V Three-Phase Isolation Dry Type Transformer Factory Price
The SG-80 400/400V Three-Phase Isolation Dry Type Transformer offers a reliable and efficient power solution for industrial and commercial applications. Designed with a dry-type isolation structure, it ensures maximum safety with no risk of oil leakage or fire hazards. The transf