HENTG POWER 33kV Earthing Transformer Oil Immersed Zig Zag Grounding Transformer for Solar Power Plants

Product Summary

HENTG POWER 33kV oil-immersed Zig Zag earthing transformer creates an artificial neutral for solar farms and MV grids. Features low zero-sequence impedance, NGR/arc suppression coil compatibility, optional 400V auxiliary winding, and IEC 60076 certification. Custom-engineered to your grounding study.

Key Attributes
Brand Name: HENTG POWER
Certification: IEC, CE
Product Custom Attributes
Highlight

33kV earthing transformer

,

oil immersed zig zag transformer

,

grounding transformer for solar plants

Product Type:
Oil Immersed Earthing Transformer
Rated System Voltage:
33kV
Winding Configuration:
Zig Zag (Zn)
Neutral Grounding Method:
NGR / Arc Suppression Coil
Zero-Sequence Impedance:
Engineered According To Grounding Requirements
Product Description
33kV Oil Immersed Zig Zag Earthing Transformer

33kV Grounding Transformer / Zig Zag Neutral Earthing Transformer from HENTG POWER, built for solar plants, wind farms, MV distribution networks, industrial & mining EPC substations.

HENTG POWER – Engineered for Reliable Power
Product Overview

The HENTG POWER 33kV Earthing Transformer is designed to build an artificial neutral point for three-phase medium-voltage power systems without available neutral connection. It is widely deployed in 33kV distribution networks, solar power plants, wind farms, industrial substations and renewable energy collector systems.

It provides a controlled zero-sequence current path during single-line-to-ground faults, enabling stable neutral grounding, earth fault protection and suppression of temporary overvoltage. This unit can be matched with Neutral Grounding Resistor (NGR) or Arc Suppression Coil (Petersen Coil) as per your network design. An optional 400V auxiliary winding is available to supply substation auxiliary loads, combining grounding and station service power supply in one single transformer.

Key Features & Benefits
Reliable Neutral Grounding for 33kV Networks

Creates artificial neutral point for delta-connected three-phase systems. Supports resistance grounding or resonant grounding and coordinated earth fault protection schemes.

Zig Zag Winding Design

Low impedance for zero-sequence fault current while maintaining high impedance for balanced positive-sequence current. Works efficiently for grounding without acting as a regular power transformer under normal operation.

Compatible with Neutral Grounding Resistor (NGR)

Connect with rated NGR to limit ground fault current. Fault current and duration are customized to match system protection and thermal withstand requirements.

Support Arc Suppression Coil Connection

For resonant grounded networks, it provides neutral access for arc suppression coil to compensate capacitive earth fault current and reduce sustained arcing fault risks.

Optional 400V Auxiliary Winding

Supply station auxiliary power: substation lighting, control panels, breaker operating mechanisms, ventilation & monitoring equipment.

Oil Immersed Outdoor Construction

Oil insulation & cooling design for medium voltage substation. Corrosion protection, oil type, cooling method and environmental adaptation can be customized for each project.

How It Works
Normal Operating Condition

Under balanced three-phase supply, zig zag windings present high impedance to positive-sequence current. Only tiny excitation current flows when no auxiliary load is connected.

Single-Line-to-Ground Fault Condition

Zero-sequence current flows through the earthing transformer and matched neutral equipment. The special winding structure creates opposing zero-sequence flux, delivering low zero-sequence impedance to form the required fault path for protection action.

Important Note: Zero-sequence impedance, allowable grounding current and thermal withstand time are calculated by engineering, not fixed for all 33kV earthing transformers.

Typical Application Scenarios
Solar Power Plants & PV Collector Networks

Utility-scale solar collector systems at 33kV busbar, to build grounding reference, control fault current and coordinate protection.

Wind Farms & Renewable Substations

Work with NGR or arc suppression coil for wind farm collector feeders, enabling reliable fault detection and equipment protection.

Urban Cable Distribution Networks

Manage high cable earth capacitance and stabilize earth fault behaviour for city 33kV cable distribution grids.

Industrial & Mining Substations

Steel plants, chemical factories and mining sites with dedicated 33kV power networks, supporting sensitive earth fault protection.

International EPC Substation Projects

Complete grounding package supply for overseas EPC projects, with custom drawings, test reports and export documentation.

Technical Specifications
Parameter Available Design / Requirement
Product Type Oil Immersed Earthing Transformer
Rated System Voltage 33kV
Winding Configuration Zig Zag (Zn)
Rated Frequency 50Hz / 60Hz
Neutral Grounding Method NGR / Arc Suppression Coil
Ground Fault Current Customized according to system study
Short-Time Duty 10s / 30s / 2h or project-specific
Zero-Sequence Impedance Engineered according to grounding requirements
Auxiliary Winding Optional 400V
Auxiliary Winding Capacity Customized according to continuous load
Cooling Method ONAN or project-specific
Installation Indoor / Outdoor, subject to design
Insulating Medium Mineral Oil / Alternative Insulating Fluid upon request
Applicable Standards IEC 60076 series / IEC 60076-6
Environmental Requirements Customized for altitude, temperature, humidity & corrosion

Final ratings and configurations subject to project requirement and engineering confirmation.

NGR vs Arc Suppression Coil Grounding
Neutral Grounding Resistor (NGR)

Limits ground fault current to a fixed value. Widely used for industrial networks and renewable collector systems requiring selective, coordinated earth fault protection.

Arc Suppression Coil (Petersen Coil)

Compensates capacitive earth fault current of the grid. Applied for resonant grounded distribution systems to reduce arcing fault and improve power continuity.

HENTG POWER manufactures earthing transformers following the grounding scheme specified by EPC contractors, utilities or electrical consultants.

Selection Guide
  • Rated System Voltage: 33kV or other required voltage level
  • System Frequency: 50Hz or 60Hz
  • Grounding Method: NGR or Arc Suppression Coil
  • Required Ground Fault Current (A)
  • Fault Withstand Duration: 10s / 30s / 2h or custom duty
  • Zero-Sequence Impedance requirement
  • 400V auxiliary winding: Yes / No, plus load kVA rating
  • Installation: Indoor / Outdoor, altitude, ambient temperature, corrosion class
  • Applicable standards & utility specifications
Why Choose HENTG POWER
  • Custom zig zag winding design & oil immersed earthing transformer manufacturing
  • Full solution for NGR and arc suppression coil grounding system
  • Optional 400V station service auxiliary winding
  • Project-tailored insulation and thermal design
  • Supply technical drawings, calculation sheets and engineering datasheets
  • Factory routine test, third-party witness inspection available
  • Export packaging and global delivery for overseas power projects
FAQ
Q: What is the purpose of a 33kV earthing transformer?

A: It creates an artificial neutral point in three-phase systems without accessible neutral, to implement defined neutral grounding protection.

Q: Difference between earthing transformer and distribution transformer?

A: Earthing transformer is designed for neutral grounding path and fault withstand duty. Distribution transformer is for continuous power voltage conversion. Earthing transformer with auxiliary winding can serve both functions.

Q: Can it connect with NGR?

A: Yes. The zig zag transformer provides neutral connection for matched NGR. Resistance, fault rating and duration need coordination with protection system.

Q: Can it supply 400V auxiliary power?

A: Yes, optional auxiliary winding can provide station service power, rated by your continuous load requirement.

Q: Suitable for solar & wind farms?

A: Yes, widely used in renewable collector networks requiring artificial neutral grounding, subject to grid code and system design.

Q: What data do you need for quotation?

A: System voltage, frequency, grounding method, fault current, fault duration, auxiliary winding requirement and site installation conditions.

Request Custom Quotation

Send your specification, single line diagram (SLD) or grounding study document to our engineering team. We will prepare technical datasheet and commercial offer for your 33kV zig zag earthing transformer project.