Double-winding OLTC 110kV Power Transformer - Trusted Solution for Long-Term Power Infrastructure HENTG POWER Double-winding OLTC 110kV Power Transformer offers a reliable solution for long-term power infrastructure with high reliability, strong voltage regulation capability, and optimized total ...
110kV double-winding power transformer
,OLTC power transformer with warranty
,long-term infrastructure power transformer
- Customizable voltage up to 132kV
- High short circuit withstand capability
- Low loss design for cost savings
- Customized transformer solutions available
- Compact dimensions and reduced weight
- Extended operational lifespan
- Ester oil insulation for superior fire safety
- 7-step stepping lap iron core structure with cold rolled grain oriented silicon steel
- High-temperature and low-temperature resistant insulation system
| Transformer Type | Oil Immersed |
|---|---|
| Rated Capacity | 40MVA |
| Rated Voltage | 110kV (customized up to 132kV) |
| Frequency | 50/60Hz |
| Phase | Three Phase |
| Winding Material | Copper / Aluminum |
| Insulation Class | A (105℃), E (120℃), B (130℃) |
| Vector Group | Dyn11 YNd1d1, etc. |
| Cooling | ONAN, KNAN, ONAF, KNAF |
| Dielectric Liquid | Mineral oil, Silicone, FR3 Oil, Midel etc. |
| Tap Changer | Off-load or on-load |
| Ambient Temperature | -45℃ ~ +50℃ |
| Standard | IEC, AS, EN, IEEE, ANSI, GOST |
| Accessories | Conservator, Pressure Relief Device, Tap Changer, Oil Temperature Indicator, Bucholz Relay, Lifting Lugs |
- K-Factor Rated
- Harmonic Mitigation
- Custom Dimensions for Size & Weight Constraints
- Custom Enclosures for Tough Environmental Conditions
- Unique Input and Output Voltages
- Low Inrush Current
- 6, 12, 18, 24 and 36 Pulse Drive Isolation Transformers
- Rectifier Duty
- High Efficiency
- Low Audible Noise
- Low Temperature Rise
- Marine Duty
- Hazardous Location


- Measurement of winding resistance
- Measurement of voltage ratio and check of phase displacement
- Measurement of short-circuit impedance and load loss
- Measurement of no-load loss and current
- Separate-source AC withstand voltage test
- Induced AC withstand voltage test
- Partial discharge measurement
- Lightning impulse test
- Temperature-rise test
- Determination of sound level for each method of cooling
- Measurement of the power taken by the fan and liquid pump motors
- Measurement of no-load loss and current at 90% and 110% of rated voltage
- Partial discharge measurement
- Measurement of sound level
- Short-circuit withstand test
- Determination of capacitances windings-to-earth, and between windings
- Vacuum deflection test on liquid immersed transformers
- Pressure deflection test on liquid immersed transformers
-
High Capacity 6000KVA 5300KVA Oil Immersed Power Transformer with 33KV High Voltage for Industrial Use
High Quality Oil Cooled 6000KVA 5300KVA Three Phase Electric Transformer 33KV 35KV 50Hz 10KVA for Electronic Our high-capacity 33kV oil-immersed power transformers are designed for industrial and utility-scale applications requiring stable power delivery under heavy loads .Available in 6000kVA and ...
-
35 KV Oil Immersed Three Phase Power Transformer 1000KVA 1600KVA for High Ambient Temperature
Three Phase Power Transformer Overview Our 35kV oil-immersed power transformers (1000kVA / 1600kVA) are specially designed and validated for tropical and high-temperature regions, making them ideal for Africa and Latin America, where ambient temperatures, humidity, dust, and grid instability present ...
-
2500kVA Oil-Immersed Power Transformer with OLTC
2500kVA/3150kVA Oil-Immersed Power Transformer with OLTC for Renewable Energy The On-Load Tap Changer (OLTC) transformer is designed for medium-voltage distribution networks requiring real-time voltage regulation under load . It is widely used in industrial parks, urban grids, and renewable energy ...