Dry Type Transformer Manufacturer Copper Aluminum Winding 315kva 400kva 630kva Step Down Power Transformer

Product Summary

Dry Type Transformers for Data Centers Mission-critical power distribution solution designed for 24/7 operation with fire safety and high reliability. Overview Modern data centers require continuous, stable, and safe power supply to support mission-critical IT infrastructure. Our Dry Type Step Down ...

Key Attributes
Payment Terms: T/T
Product Custom Attributes
Highlight

dry type transformer copper winding

,

step down power transformer 630kva

,

aluminum winding dry type transformer

Productname:
Dry Type Transformer
Coil Number:
Three Windings, Multi Winding
Type:
Dry Type
Coolingmethod:
Air Cooled
Noiselevel:
Low Noise Operation
Cooling:
ANAF Or Customized
Powerrating:
Up To 5000 KVA
Application:
Power
Windingmaterial:
Copper Or Aluminum
Voltage:
6.6kv-35kv
Efficiency:
High Efficiency
Product Description
Dry Type Transformers for Data Centers
Mission-critical power distribution solution designed for 24/7 operation with fire safety and high reliability.
Overview
Modern data centers require continuous, stable, and safe power supply to support mission-critical IT infrastructure. Our Dry Type Step Down Transformers (315kVA / 400kVA / 630kVA) are purpose-built for data center power distribution, ensuring maximum reliability, zero oil-related risk, and long-term operational stability.
With oil-free insulation, low partial discharge design, and high thermal endurance, these transformers are ideal for indoor MV/LV rooms, UPS systems, PDUs, and modular data centers.
Why Dry Type Transformers Are Preferred in Data Centers
Unlike conventional oil-immersed transformers, dry type transformers eliminate fire and leakage risks, allowing installation closer to IT loads, reducing power losses and improving overall efficiency.
Key reasons data centers choose dry type transformers:
  • No oil, no fire hazard
  • Indoor installation capability
  • High reliability under continuous load
  • Minimal maintenance requirement
  • Compliance with international data center standards
Core Design Highlights
  • Cast Resin or VPI Dry-Type Insulation - High dielectric strength with excellent resistance to humidity and dust
  • Copper or Aluminum Windings - Copper for lower losses and higher efficiency; Aluminum for optimized cost-performance
  • Low Partial Discharge Design - Suitable for sensitive servers and IT equipment
  • Advanced Thermal Design - Continuous full-load operation with optional forced air cooling (AF) for overload scenarios
  • Low Noise Operation - Ideal for indoor technical rooms
Data Center Industry Solutions
Data Center Pain Point Operational Risk Our Solution
Fire safety concerns Oil fire & leakage risk Oil-free dry type design
24/7 continuous load Overheating & insulation aging High thermal margin design
Sensitive IT equipment Voltage instability & PD Low PD, stable output
Limited maintenance windows Downtime risk Maintenance-free insulation
Indoor installation Space & safety constraints Compact, indoor-safe structure
Proven Application Scenarios
Our dry type transformers are widely used in:
  • Enterprise Data Centers
  • Colocation & Hyperscale Data Centers
  • Edge & Modular Data Centers
  • Cloud Computing Facilities
  • Telecom & Financial Data Centers
Typical Installation Points:
  • MV/LV distribution rooms
  • UPS input/output transformers
  • PDU and RPP systems
  • Containerized and modular data centers
Reference Application Case
Project Type: Modular Data Center Power Distribution
Transformer Rating: 2 * 630kVA Dry Type Transformers
Voltage: 10kV / 0.4kV
Application: UPS input and LV distribution
Key Requirements:
  • Indoor installation
  • Zero fire risk
  • Continuous 24/7 operation
Result:
  • Stable power supply with no unplanned downtime
  • Reduced maintenance workload
  • Compliance with data center fire safety standards
Safety & Compliance
  • Oil-free, non-flammable construction
  • Self-extinguishing insulation materials
  • No environmental contamination risk
  • Compliant with IEC 60076 / IEC 60076-11
  • Insulation Class F or H (optional)
Suitable for Tier II / Tier III data center infrastructures.
Typical Technical Parameters
  • Rated Capacity: 315kVA / 400kVA / 630kVA
  • Voltage: 6.6kV / 10kV / 11kV / 20kV → 400V / 415V
  • Frequency: 50Hz / 60Hz
  • Vector Group: Dyn11 (customizable)
  • Cooling: AN / AF
  • Protection Degree: IP00 / IP23 / Enclosure Optional
Optional Monitoring & Accessories
  • PT100 / PTC temperature sensors
  • Intelligent temperature controller
  • Alarm & trip outputs
  • Remote monitoring interface
  • Anti-vibration mounting system