SCB13 Three-Phase Dry Type Transformer for Data Centers Low Loss Distribution Transformer 10kv Output 60hz
SCB13 Three-Phase Dry Type Transformer for Data Centers (10kV, 60Hz, Low Loss) The SCB13 three-phase dry type transformer is specially engineered to meet the strict requirements of data centers, IT facilities, and mission-critical infrastructure . With a 10kV output and 60Hz frequency , it delivers stable and efficient power distribution for servers, cooling systems, and sensitive electronic equipment. Built with cast resin insulation technology , the SCB13 transformer
The SCB13 three-phase dry type transformer is specially engineered to meet the strict requirements of data centers, IT facilities, and mission-critical infrastructure. With a 10kV output and 60Hz frequency, it delivers stable and efficient power distribution for servers, cooling systems, and sensitive electronic equipment.
Built with cast resin insulation technology, the SCB13 transformer ensures fire resistance, moisture resistance, and excellent dielectric strength, making it highly reliable in environments where safety and continuity of operation are paramount. Its low loss and high efficiency design significantly reduces energy consumption and operating costs, fully aligning with green data center initiatives.
- High Reliability – Guarantees stable power for uninterrupted IT operations
- Low Loss & Energy Saving – Reduced no-load and load losses, lowering electricity costs
- Fire & Moisture Resistant – Safe for indoor installation, no oil leakage risks
- Low Noise Operation – Quiet performance, suitable for enclosed server rooms
- Flexible Cooling Options – Natural air cooling (AN) or forced air cooling (AF) for different load demands
- Long Service Life – Optimized coil and core design ensures durability under continuous operation
- Data centers & server farms
- Cloud computing facilities
- Financial institutions & telecom hubs
- Hospitals & critical care facilities
- Commercial complexes & smart buildings
Data centers require uninterrupted power supply, high efficiency, and maximum safety. The SCB13 transformer provides stable voltage output, superior insulation performance, and low operating costs, ensuring that critical IT infrastructure remains secure and efficient.
| Rated capacity (KVA) | Vector Group | Voltage Combination | No-load loss | Load loss | No-load current | Impedance | ||
|---|---|---|---|---|---|---|---|---|
| HV | Tapping range | LV | ||||||
| 30 | Yyn0 / Dyn11 | 10 6.3 6 |
±5% ±2X2.5% (+3/-1)X2.5% |
0.4 | 135 | 640 | 2 | 4.0 |
| 50 | 195 | 900 | 2 | 1.5 | ||||
| 80 | 265 | 1240 | 1.5 | 1.3 | ||||
| 100 | 290 | 1410 | 1.5 | 1.3 | ||||
| 125 | 340 | 1660 | 1.1 | 1.1 | ||||
| 160 | 385 | 1910 | 1.3 | 1.1 | ||||
| 200 | 445 | 2270 | 1.1 | 1.1 | ||||
| 250 | 515 | 2480 | 1 | 1 | ||||
| 315 | 635 | 3120 | 1 | 1 | ||||
| 400 | 705 | 3590 | 1 | 1 | ||||
| 630 | 965 | 5360 | 0.85 | 0.85 | ||||
| 630 | 935 | 5290 | 0.85 | 0.85 | ||||
| 800 | 1090 | 6260 | 0.85 | 0.85 | ||||
| 1000 | 1270 | 7310 | 0.85 | 0.85 | ||||
| 1250 | 1500 | 8720 | 0.85 | 0.85 | ||||
| 1600 | 1760 | 10500 | 0.85 | 0.85 | ||||
| 2000 | 2190 | 13000 | 0.7 | 0.7 | ||||
| 2500 | 2590 | 15400 | 0.7 | 0.7 | ||||
-
Epoxy Resin Dry Type Distribution Transformer 80 Kva 3 Phase With Triple Winding Coil
Epoxy Resin Dry Type Distribution Transformer 80 Kva 3 Phase With Triple Winding Coil Product Specifications Attribute Value Type Power transformer, distribution transformer, Dry Type Transformer Frequency 50Hz, 60Hz Winding Material Copper Application Power Phase Three Coil Structure Layered Winding Coil Number Triple-winding coil Input Voltage 10kV Output Voltage 400V Cooling Method Fan System Vector Group Dyn11/Yyn0 Transformer type Dry Isolation Insulation Material Epoxy
-
50Hz Medium Voltage Dry Type Transformer 30KVA Step Up Down Instrument Transformer
50Hz Medium Voltage Dry Type Transformer 30KVA Step Up Down Instrument Transformer Product Specifications Attribute Value Type Distribution transformer Material Copper, Copper Winding Frequency 50Hz, 60Hz Shape Rectangle Winding Material Copper Application Potential Phase Three Coil Structure TOROIDAL Coil Number Multi-winding coil Input Voltage 10kV, 6kV, 6.3kV Output Voltage 0.4kV Rated Capacity 30KVA-2500KVA Cooling Method ANAF Core Material CRGO Silicon Steel Core Feature
-
3 Phase Power Transformer 800KVA 1000KVA 1250KVA Dry Type Step Up Transformer
3 Phase Power Transformer 800KVA 1000KVA 1250KVA Dry Type Step Up Transformer Product Specifications Attribute Value Type Distribution transformer, Power Isolation Transformer Frequency 50Hz, 60Hz Winding Material Aluminum Application Power Phase Three Coil Structure Layered Winding Coil Number Triple-winding coil Input Voltage 3kV, 6kV, 10kV, 15kV, 35kV, 69kV, 110kV, 220kV, 400kV, 115kV, 132kV Output Voltage 5V, 400V, 208V, 200V, 415V, 127V, 11kV, 12V, 24V, 48V, 110V, 220V,