Transformator HV Mv Listrik Terendam Minyak 400kva 1000kva 3 Fase Ynd11 Sambungan Vektor
Oil Immersed Electrical HV/MV Transformer 400kVA - 1000kVA 3 Phase Ynd11 Vector Connection Product Specifications Type Distribution Transformer, Oil-filled Transformer Material Copper Winding Frequency 50Hz, 60Hz Phase Three Input Voltage 6kV, 10kV, 15kV, 35kV, 69kV, 100V, 110kV Output Voltage 400V, 208V, 200V, 415V, 127V, 9V Insulation Class Class F Vector Connection Ynd11 Key Features Compliance with IEC, ANSI, and IEEE standards for safety and performance Compact and
3 Fase Elektrik Hv Mv Transformer
,Ynd11 Transformer Sambungan Vektor Hv Mv
| Tipe | Transformator Distribusi, Transformator Berisi Oli |
| Material | Lilitan Tembaga |
| Frekuensi | 50Hz, 60Hz |
| Fasa | Tiga |
| Tegangan Masukan | 6kV, 10kV, 15kV, 35kV, 69kV, 100V, 110kV |
| Tegangan Keluaran | 400V, 208V, 200V, 415V, 127V, 9V |
| Kelas Isolasi | Kelas F |
| Sambungan Vektor | Ynd11 |
- Kepatuhan terhadap standar IEC, ANSI, dan IEEE untuk keselamatan dan kinerja
- Konstruksi yang ringkas dan kokoh untuk penghematan ruang dan penggunaan yang tahan lama
- Desain hemat energi dengan pengurangan kerugian tanpa beban dan pengoperasian kebisingan rendah
- Pengubah tap tanpa energi untuk pengaturan tegangan yang fleksibel
- Penyegelan hermetis untuk mencegah masuknya kelembaban dan menjaga kualitas oli
- Dioptimalkan untuk jaringan tegangan menengah 35kV di zona industri dan gardu utilitas
- Catu daya tiga fasa yang stabil untuk peralatan tugas berat
- Sistem pendingin terendam oli yang efisien menggunakan oli isolasi mineral/ester
- Pengurangan jejak karbon melalui minimalisasi kehilangan energi
- Solusi hemat biaya dengan umur panjang dan perawatan rendah
| Kapasitas (kVA) | HV (kV) | LV (kV) | Kerugian Tanpa Beban (W) | Kerugian Saat Beban (W) | Arus Tanpa Beban (%) | Impedansi Hubung Singkat (%) |
|---|---|---|---|---|---|---|
| 630 | 35 | 3.15/6.3/10.5 | 830 | 7870 | 1.1 | 6.5 |
| 800 | 35 | 3.15/6.3/10.5 | 980 | 9410 | 1.0 | 6.5 |
| 1000 | 35 | 3.15/6.3/10.5 | 1150 | 11540 | 1.0 | 6.5 |
| 1250 | 35 | 3.15/6.3/10.5 | 1410 | 13940 | 0.9 | 6.5 |
| 1600 | 35 | 3.15/6.3/10.5 | 1700 | 16670 | 0.8 | 6.5 |
| 2000 | 35 | 3.15/6.3/10.5 | 2180 | 18380 | 0.7 | 6.5 |
| 2500 | 35 | 3.15/6.3/10.5 | 2560 | 19670 | 0.6 | 6.5 |
| 3150 | 35-38.5 | 3.15/6.3/10.5 | 3040 | 23090 | 0.56 | 7.0 |
| 4000 | 35-38.5 | 3.15/6.3/10.5 | 3620 | 27360 | 0.56 | 7.0 |
| 5000 | 35-38.5 | 3.15/6.3/10.5 | 4320 | 31380 | 0.48 | 7.0 |
-
35 KV Power Transformer Variable Voltage Oil Dipendam Tiga Fase Power Transformer 1000KVA 1600KVA
Three Phase Power Transformer Overview High-performance 35KV oil-immersed electricity transformers designed for industrial and utility applications, available in 1000KVA and 1600KVA capacities with variable voltage capabilities. Key Features Three-phase power distribution system compatibility 35KV voltage rating for high-voltage applications Oil-immersed cooling system for optimal thermal management Variable voltage output capabilities Available in 1000KVA and 1600KVA
-
Transformator daya terendam minyak 2500kVA dengan OLTC
2500kVA/3150kVA Oil-Immersed Power Transformer with OLTC for Renewable Energy The On-Load Tap Changer (OLTC) transformer is designed for medium-voltage distribution networks requiring real-time voltage regulation under load . It is widely used in industrial parks, urban grids, and renewable energy integration. The OLTC mechanism allows automatic or manual voltage adjustment without interrupting power supply, ensuring continuous, stable electricity . Key Application Specially
-
2500KVA 3150KVA Langkah Turun Transformator Distribusi Teluk 11KV 33KV Tiga Fase Power Transformator
2000KVA 2500KVA 3150KVA Oil Immersed Step Down Transformer Three Phase Distribution Transformer - 11KV/33KV The 2500kVA and 3150kVA Step-Down Oil-Immersed Distribution Transformers are designed for medium- to high-capacity power distribution systems , providing reliable voltage reduction from 11kV or 33kV to low-voltage levels for industrial, utility, and infrastructure applications. Robust Oil-Immersed Design These transformers adopt a mineral oil–immersed structure ,