Three Phase 2000kva Pad Mounted Oil Immersed Transformer with 11kV - 500kV Range and ≥ 98% Efficiency for High Frequency Applications
Three Phase 2000kva Pad Mounted Transformer Electrical Transformers High Frequency Oil Filled Transformer Product Overview High-performance three-phase pad mounted transformer designed for efficient power distribution with robust construction and environmental adaptability. Key Features Aesthetic ...
11kV - 500kV Pad Mounted Transformer
,≥ 98% Efficiency Oil Immersed Transformer
,High Frequency Electrical Transformer
High-performance three-phase pad mounted transformer designed for efficient power distribution with robust construction and environmental adaptability.
- Aesthetic and Durable Design: Modern appearance with excellent environmental resistance, seamlessly integrating with surrounding architecture.
- Optimal Load Placement: Enables deployment near medium-voltage load centers, reducing distribution line length and improving power quality.
- Cost-Efficient Operation: Requires minimal infrastructure and maintenance, delivering lower total cost of ownership.
- Sustainable Solution: Modular design allows for relocation and reuse, supporting environmental sustainability goals.
| Rated Frequency | Hz | 50 |
| Rated Voltage | kV | 6, 10, 35 |
| Max Working Voltage | kV | 6.9, 11.5, 40.5 |
| Industrial Frequency Voltage-resisting | kV | 32/36, 42/48, 95/118 |
| Thunder and Lighting Voltage-resisting | kV | 60/70, 75/85, 185/215 |
| Rated Current | A | 400, 630 |
| Rated Brief-period Current-resisting | kA | 12.5(2s), 16(2s), 20(2s) |
| Rated Crest Value Current-resisting | kA | 32.5, 40, 50 |
| Rated Voltage | V | 380, 220 |
| Rated Current Of Major Circuit | A | 100-3200 |
| Rated short-circuit Current-resisting | kA | 15, 30, 50 |
| Rated Crest Value Current-resisting | kA | 30, 63, 110 |
| Branch Circuit | A | 10-800 |
| Quantity Of Branch | line | 1-12 |
| Compensation Circuit | kVAR | 0-360 |
| Rated Capacity | kVA | 50-2000 |
| Short-circuit Impedance | % | 4, 6 |
| Scope Of Branch Connection | ±2x2.5%, ±5% | |
| Vector Group | Yyn0, Dyn11 |
-
Aanpasbare boxtype-substation met koperen spoel en 1600kVA 10kV voor efficiënte stroomdistributie
Aanpasbaar Box Type Substation met Koperen Spoel en 1600kVA 10kV voor Hoogrendement Stroomverdeling Consultatieproces Stap 1: We reageren binnen 1 uur op aanvragen met geschikte transformatoraanbevelingen op basis van uw vereisten. We bieden concurrerende offertes en flexibele betalingsvoorwaarden. ...
-
Driefasige transformatorstation in doosvorm met 400V-690V uitgangsspanning en 20kV nominale spanning voor stroomverdeling
Driefasige Box Type Substation met 400V-690V Uitgangsspanning en 20kV Nominale Spanning voor Stroomverdeling Consultatieproces Stap 1: We reageren binnen 1 uur op vragen en bevelen geschikte transformatoren aan op basis van uw vereisten. We bieden concurrerende offertes en flexibele betalingsvoorwaa...
-
PV Inverter Boost Cabinet 500kW. Geïntegreerde zonne-energie omzetting en opslag oplossing.
PV-omvormer Boost-kast 10-500kW | Geïntegreerde oplossing voor zonne-energieconversie en -opslag CONSULTATIEPROCES Stap 1: We reageren binnen 1 uur op uw aanvraag en bevelen een geschikte transformator aan op basis van uw behoeften. Tegelijkertijdsturen we u redelijke offertes en betalingsvoorwaarde...